Descargar Imprimir esta página

STAMOS S-LS-24 Manual De Instrucciones página 4

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 12
U S E R M A N U A L
The operation manual must be reviewed.
Never dispose of electrical equipment together
with household waste.
This machine conforms to the CE declarations.
Attention! Hot surface may cause burns.
PLEASE NOTE! Drawings in this manual are for
illustration purposes only and in some details
it may differ from the actual machine.
The original operation manual is in German. Other
language versions are translations from German.
SAFETY INSTRUCTIONS
General safety information for the use of electrical devices:
To avoid injury from fire or electric shock, please ensure
compliance with safety instructions when using this device.
Please read the instruction carefully and make sure that
you have understood it well. Keep the manual near the
equipment to be able to read it at any time. Always use
current sources connected to the ground and providing the
necessary voltage (indicated on the label on the device).
If you have any doubt, let an electrician check that your
outlet is properly grounded. Never use a damaged power
cable. Do not open the unit in damp or wet environment,
or if you are wet yourself. Protect the unit of solar radiation.
Use the device in a protected location to avoid damaging
the equipment or endangering others. Make sure the
device is able to cool and avoid placing it too close to other
devices that produce heat. Before cleaning, disconnect it.
Use a soft damp cloth for cleaning. Avoid using detergent
and make sure that no liquid enters the unit. No internal
element of this device needs to be maintained by the user.
An opening of the device without our approval leads to
a loss of warranty.
SAFETY GUIDELINES
1.
Please
read
these
instructions
carefully
understand them before operating the device!
Please observe the safety guidelines carefully in
order to prevent damages through improper use!
2.
Please keep this manual available for future
reference. If this device is passed on to third parties,
the manual must be passed on with it.
3.
Only use this device indoors and for its intended use.
4.
We do not offer any warranty for damages resulting
from improper use or incorrect operation.
5.
Check before first use whether main voltage type
and current comply with the indicated data on the
type plate.
6.
This device is not intended to be used by persons
(including children) with limited physical, sensory
or mental aptitude or lack of experience and/or
knowledge unless they are supervised by a person
responsible for their safety or have received
instruction from this person as to how the device is
used.
7.
ELECTRICAL SHOCK HAZARD! Do not attempt to
repair the unit yourself. In case of device failures,
repair must be done by qualified experts.
8.
Please check main plug and power cable regularly.
If the power cable for this device is damaged, it has
to be replaced by the manufacturer or its customer
service or another qualified person in order to
prevent hazards.
6
EN
9.
Prevent damages to the power cable by avoiding
squeezing, bending or rubbing it on sharp edges and
keep it away from hot surfaces and open flames.
10.
ATTENTION! DANGER TO LIFE! While cleaning, never
immerse the device in water or other liquids.
11.
Some parts of this appliance can get very hot. To
avoid injury, be careful when touching these surfaces.
12.
Make sure the hot air can circulate well and place the
device more than10 cm away from walls and other
electrical devices. Aerate well the working area.
13.
Do not place the device close to combustible
materials.
TECHNICAL DETAILS
Product name
Power Supply Unit
Model
S-LS-24
Voltage [V]
230
Power [W]
315
Frequency [Hz]
50
Working temperature [°C]
0 – 40
Storage temperature [°C]
-20 – 80
Relative working humidity
<80%
Relative storage humidity
<80%
Insulation resistance [MΩ]
≥100
Leakage current [mA]
≤1
Dimensions [mm]
396x248x180
Weight [kg]
9,75
Channel I/II (independent operation)
DC voltage adjustment
0 – 31
and
range [V]
Current adjustment range [A]
0 – 5,2
Line regulation coefficient
CV≤0.01%+1mV
CC≤0.2%+1mA
Line regulation coefficient
CV≤0.01%+5mV(I≤3A)
under load
CV≤0.01%+2mV(I>3A)
CC≤0.2%+5mA(I≤3A)
CC≤0.2%+10mA(I>3A)
Ripples
CV≤0.5mVrms(I≤3A)
CV≤1mVrms(I>3A)
CC≤3mArms(I≤3A)
CC≤5mArms(I≤3A)
Accuracy
±0.5% + 2
Channel I/II (parallel)
Line regulation coefficient
≤1mV
Line regulation coefficient
≤20mV
under load
Ripples
CV≤0.5mVrms(I≤6A)
CV≤1mVrms(I>6A)
Rev. 07.09.2018
Product name
Power Supply Unit
Channel I/II (serial)
Line regulation coefficient
≤1mV
Line regulation coefficient
≤30mV
under load
Ripples
≤1mVrms
Channel III
DC voltage adjustment
(2.5/3.3/5) ± 0.1
range [V]
Current adjustment range [A]
3A
Line regulation coefficient
≤1mV
Line regulation coefficient
≤10mV
under load
Ripples
≤1mVrms
USAGE PURPOSE
The laboratory power supply is a device used to supply
direct current at a certain voltage to external devices.
It is used at electronic equipment workshops as well as
laboratories and production plants.
Any damage resulting from a non-conform use of the
device is payable by the user!
PRINCIPLE OF OPERATION
Assembly
6
4
5
3
2
1
9
8
7
20 10
11
19 18
17 16 15 14 13 12
1.
Channel I coarse voltage adjustment knob
2.
Channel I fine voltage adjustment knob
3.
Channel I coarse current adjustment knob
4.
Channel I parameters display
5.
Channel II parameters display
6.
Diodes
7.
Channel II coarse voltage adjustment knob
8.
Channel II fine voltage adjustment knob
9.
Channel II coarse current adjustment knob
10.
Channel I and II operating mode selector
11.
Power supply On/Off switch
12.
Channel II (+) pole
13.
Channel II earth
14.
Channel II (-) pole
15.
Channel I (+) pole
16.
Channel I earth
17.
Channel I (-) pole
18.
Channel III (+) pole
19.
Channel III (-) pole
20.
Channel III output voltage selector switch
Rev. 07.09.2018
EN
2
3
1
4
5
6
8
7
1.
Channel I line regulation indicator
2.
Channel I load regulation indicator
3.
Channel II line regulation indicator
4.
Channel II load regulation indicator
5.
Channel I and II parallel operation mode indicator
6.
Channel I and II independent operation mode
indicator
7.
Channel I and II serial operation mode indicator
8.
Channel III voltage indicator
BEFORE FIRST USE
Upon receipt of the goods, check the packaging for
integrity and open it. If the packaging is damaged, please
contact your transport company and distributor within 3
days, and document the damages as detailed as possible.
Do not turn the package upside down! When transporting
the package, please ensure that it is kept horizontal and
stable. Please keep all packaging materials (cardboard,
plastic tapes and styrofoam), so that in case of a problem,
the device can be sent back to the service centre in
accurate condition.
DISPOSING OF PACKAGING
The various items used for packaging (cardboard, plastic
straps, polyurethane foam) should be conserved, so that
the device can be sent back to the service center in best
conditions in case of problem!
INSTALLING THE APPLIANCE
Appliance location
The work surface where the device will be located must be
suitable for the size of the appliance, please refer to the
measurements.
The work surface must be levelled, dry, heat-resistant and
at a fitting height from the ground to enable a proper use
of the device.
The power cord connected with the appliance must be
properly grounded and correspond to the technical details.
DC POWER SUPPLY OPERATION
1.
Place the device on a stable surface and connect the
power cable to a power source in accordance with
the power supply name plate.
2.
Use on/off switch (11) to turn on the power supply.
3.
Read parameters of the power source connected to
the device.
4.
Using channel III current will be constant, whereas
the voltage can be set using the selector (20). Once
the output voltage parameters have been set,
connect the external load to appropriate poles (+)
and (-).
5.
For the first two channels, select working mode using
the selector (10).
7

Publicidad

loading