INSERTING BATTERIES
1.
Remove the battery compartment cover.
2.
Insert the batteries into the compartment observing
the polarity
3.
Replace the battery compartment cover.
Note: If you need to replace the batteries with new ones,
proceed in the same way as above.
CONFIGURING THE SET
A. Transmitter
1.
After installing the batteries, the transmitter will start
for a short time and this will be indicated by the LED
light. Then the LED will turn off and the transmitter
will go into normal operation mode.
2.
A transmitter will start searching for a radio time
signal. If a signal reception is correct, a diode will
flash and, afterwards, light for several seconds.
3.
When operating in a standard mode, a diode will
light for a moment every 48 sec.
B. Receiver
1.
After the batteries are installed, the receiver will start.
2.
A receiver will start searching for a transmitter signal.
The icon of a radio signal reception will appear on a
display.
3.
When the receiver detects a transmitter signal, it will
switch to a standard operation mode.
4.
When no radio signal is detected, the device restart
searching every 6 hours.
5.
If the signal is lost or the measurement results are
not displayed:
a)
press and hold the [RESET] button on the
EN
transmitter;
b)
take out the batteries and after about 2
minutes put them back into the battery compartment
of the receiver.
TRANSMITTER INSTALLATION
A. Mounting bracket
1.
Unpack the transmitter components and check their
condition.
2.
Attach a metal flat bar to the bottom of the
transmitter.
3.
Insert the "U" pins into the holes of the flat bar and
secure them with the nuts.
B. Wind speed meter (anemometer)
1.
Mount the measuring cups on the shaft. Secure by
tightening the bolt.
Note: pay attention that the anemometer cups can
move freely. Too tight mount can interfere with
measurement results.
C. Wind direction indicator (anemoscope)
1.
Mount the weathercock on the shaft by sliding it all
the way to the opposite side of the anemometer and
secure it by tightening the bolt.
Note: make sure that the weathercock can move
freely.
D. Outdoor installation
1.
Place the transmitter in its final location using the
mounting bracket (post ø = 1 "÷ 2" not included in
the set).
2.
When installing a transmitter in a target place,
take account for a north direction and install the
transmitter according to the direction which is
marked on a transmitter surface.
3.
Level the transmitter using a level which is placed on
its surface.
Caution: Poor levelling of the transmitter may disturb
measurement results.
RECEIVER INSTALLATION
1.
It is recommended to install a receiver on a flat,
vertical surface to provide a proper transmitter signal
reception.
Caution: a distance from a transmitter, the
appearance of barriers (e.g. walls), electromagnetic
and radio waves may reduce the power of a signal.
3.3. DEVICE USE
Caution: the device is operated with a touchscreen. Touch a
proper panel on a receiver display and modify parameters
with +/- or ON/OFF.
To switch between individual settings of a given range
(e.g. temperature), touch the screen several times in the
selected area (e.g. [A]) until the item to be changed appears
(e.g. resetting the records).
16
3.3.1 TEMPERATURE AND HUMIDITY PARAMETERS
1
3
2
4
Touch a receiver panel in [A] area to configure temperature
and humidity parameters.
After selecting the appropriate item to be changed, the
+/- and ON / OFF buttons will flash and modification will
be possible.
1.
Indoor temperature „TEMP IN" (changing units,
alarms, max. and min. records)
2.
Outdoor temperature „TEMP OUT" (changing units,
alarms, max. and min. records)
3.
Indoor air humidity „HUMIDITY IN" (alarms, max. and
min. records)
4.
Outdoor air humidity „HUMIDITY OUT" (alarms, max.
and min. records)
3.3.2 WIND PARAMETERS
2
1
Touch a receiver panel in [B] area to configure wind parameters.
After selecting the appropriate item to be changed, the +/- and
ON / OFF buttons will flash and modification will be possible.
1.
Wind speed „WIND" (average or the gusts of wind,
changing units, alarms, records)
2.
Wind direction (alarms)
3.
Press and hold „WIND" for 3 sec. to reset results to a
current reading value.
3.3.3. RAINFALL PARAMETERS
1
Touch a receiver panel in [B] area to configure rainfall
parameters.
After selecting the appropriate item to be changed, the
+/- and ON / OFF buttons will flash and modification will
be possible.
1.
Rainfall „RAIN" (measurement time, units, alarms,
max. records)
2.
Press and hold „RAIN" for 3 sec. to reset measurement
results to „0" value.
3.3.4. WEATHER FORECASTING
Touch a receiver panel in [C] area to configure weather
forecasting parameters.
After selecting the appropriate item to be changed, the
+/- and ON / OFF buttons will flash and modification will
be possible.
1.
Waether forecasting „TENDENCY" (a cloudiness level,
an air pressure benchmark, storms)
3.3.5. ATMOSPHÄRENDRUCK
1
2
Touch a receiver panel in [D] area to configure air pressure
parameters.
After selecting the appropriate item to be changed, the
+/- and ON / OFF buttons will flash and modification will
be possible.
1.
Air pressure value „PRESSURE" (relative and absolute
values, units, alarms, max. and min. records)
2.
Air pressure chart „PRESSURE HISTORY" (changing
the time spread of measurements)
3.3.6 TIME AND DATE SETTINGS
1
2
Touch a receiver panel in [E] area to configure time and
date parameters.
After selecting the appropriate item to be changed, the
+/- and ON / OFF buttons will flash and modification will
be possible.
17
EN