5.7. The showcase shall be washed and cleaned during sanitary days. Frequency
thereof shall be governed by the applicable regulations. To do this, the following actions
shall be taken:
-
disconnect the showcase from the mains
-
carefully clean all showcase surfaces where the food items used to be with non-
abrasive detergents
-
power on the showcase after it dries out
when the temperature of +5°С is achieved in the evaporator box, load precooled
-
food items to the showcase.
5.8. The following works shall be done by the employees of the company that uses the
product during the periods between maintenance and repair activities:
a) monitoring of the product condition, its proper loading, and the condensate
withdrawal system
b) visual inspection of the motor unit: the pipelines shall be check for any loss of
tightness: oil spots in the dismountable connection indicate a fluorocarbon refrigerant leak
c) daily cleaning and wiping of the product after its operation period is complete
d) visual control of the effective volume temperature
e) periodic (at least once every month) cleaning of the condenser to remove any dust
and dirt.
5.9. Maintenance and repair of the products shall be carried out only by specialized
repair-assembly facilities entitled to conduct such activities. The following shall be done
during maintenance activities:
-
tightness of the pipelines shall be checked
-
passport features of the showcase shall be checked
-
if required, adjust the showcase features
-
proper tightening of the threaded connections shall be checked
-
cooling unit condenser shall be cleaned
-
condition of the grounding shall be checked; transition resistance shall be
measures: it shall be maximum 0.1 Ohm
5.10. The product may be transported with any means of transportation except for
airborne ones in line with the cargo transportation regulations applicable to the respective
type of transport. The vehicle speed transporting the Product shall not exceed 60 km/h.
Transportation and storage conditions shall follow storage condition group 4 under GOST
15150-69, with the temperature to be minus 35 °С as a minimum. Storage condition group
4 under GOST 15150-69 means any sheds or rooms where the temperature and humidity
fluctuations insignificantly differ from those in the open air.
Showcases may be stacked in three layers.
5.11. Only the persons taken the instructions on safety precautions and provided with
the handling rules for the Product can use the Product.
6. ACCEPTANCE, CONSERVATION AND PACKAGE CERTIFICATE
The product complies with the technical specifications and has been found ready for
operation.
QA/QC stamp
16
7. MANUFACTURER'S WARRANTY