Operation
Installing thermal imaging module on the optical device
• Remove the eyepiece cover (2).
• Select the Ring Adapter (15) (sold separately) with the insert (14) of the
desired diameter depending on the outer diameter of the lens of your optical
device (13) (see table). The designation 42 mm / 50 mm / 56 mm in the name
of the adapter means the lens diameter of the optical device.
Selection table for optical device inserts
The internal diameter of the insert needs to match the outer diameter of the
objective lens housing of the daylight optical device it is being installed on.
Ring Adapter
model
Insert internal diameter, mm
45.5
46
46.5
PSP Ring
47
Adapter 42 mm
48
49
50
51.6
53.4
55
PSP Ring
56
Adapter 50 mm
57
58
59
60
61
62
PSP Ring
Adapter 56 mm
63
64
65
• Screw together the Ring Adapter (15) and the thermal imaging module along
the threads of the mount (20). The recommended lever (19) position is on the
right (see Fig.).
• Evenly tighten the screws (16) until it just grips onto the Krypton mount (20)
(they will be fully tightened in a later step)
• Push the insert (14) of your choice into the Ring Adapter (15) until it stops.
• Before installing the Ring Adapter (15) onto the optical device, it is
recommended to degrease the lens body of the optical device (13).
• Mount the Ring Adapter with the insert onto the lens of the daylight optical
device (13) as far as it will go.
• Move the lever (19) from its initial OPEN position to the CLOSE position.
• Ensure that the Ring Adapter fits snugly against the lens housing and there
is no movement.
• If the Ring Adapter with the thermal imaging module moves freely relative to
the lens of the optical device (13), do the following:
- Loosen the locking screw (17) with a 2mm Allen key.
- Tighten the screw (18) using a 4mm Allen key. The clamping force should
ensure the tight operation of the lever (19), while the Ring Adapter with
the thermal imaging module should not move relative to the body of the
optical device (13). If necessary, tighten or loosen the screw (18) to operate
the lever (19) in the best way possible.
- Tighten the locking screw (17) as far as it will go.
Suitable for lens housing of daylight optical
devices with an outer diameter of, mm
45.5
46
46.5
46.7-47.6
47.7- 48.6
48.7-49.6
49.7-50.6
51.6
53.4
54.7-55.6
55.7-56.6
56.7-57.6
57.7-58.6
58.7-59.6
59.7-60.6
60.7-61.6
61.7-62.6
62.7-63.6
63.7-64.6
64.7-65.6
4