7.1 Removing air bubbles / checking the oil level
To remove the air from the system or to check the oil level the lifting carriage has to be taken off the hydraulic unit.
When you unscrew the screw you remove the air from the system.
Check the oil level. The oil should be up to the lower edge of the bore.
If applicable refill the oil in accordance with ISO VG 46 and then screw in the screw hand-tight.
8. Declaration of conformity
Herewith we, the DENIOS AG, Dehmer Straße 58-66, D 32549 Bad Oeynhausen, declare that the product
complies with following guidelines.
Type:
Safe working load:
EC Directives
Machinery directive 2006/42/EC
Harmonised standards applied
EN 1494
DIN EN 1757
EN 349
EN ISO 14121
EN 12100 -1,-2
EN 13857
Person responsible for documentation
Mr. Dr. Ing. R. Adenstedt
Head of engineering
Fasstransporter DT250 /Fasslifter RT250
164380 / 164387, 180867, 180868
Open the relief valve (6).
Loosen the retaining rings and then remove the bolts and rollers.
When you have then lifted up the lifting
carriage you can see the oil filler screw.

EC Declaration of Conformity

DT drum transporter./.RT drum lifter
Seite 9 von 18 Seiten
250 kg