CAMERA TECHNICAL FEATURES (Art. 68TC).
-
CCD 1/4" color sensor
-
3,7mm F4.5 auto-iris lens with non-adjustable focus
-
Video signal standard PAL type G, 625 lines, 50 images
-
Manual traversing on the vertical and horizontal axis
-
Effective picture: 500(H)x582(V) PAL
-
Horizontal resolution: 350 TV lines or Greater
-
Electronic iris (shutter).
-
Video output voltage 1Vpp on 75Ohms
-
Operating temperature -5° +45°C
-
Minimum lighting level 4 lux
-
Subject lighting by means of white light LEDs
- Name-tag lighting through LEDs
-
Built-in speech unit
-
Removable terminal block
-
Monitor call push-button.
-
Output for control of lighting floodlight by relay type 170/101
- Lock release control with same timing as command from the monitor (1
second, not adjustable).
- Supply voltage from the bus.
- External dimensions: 80x120x25 mm.
CAMERA TECHNICAL FEATURES (Art. 68TU).
- ¼'' CCD B/W sensor
- 3,7 mm lens with F4,5 fixed focus
- Automatic brightness control
- Manual traversing on the vertical and horizontal axis
- Standard video signal CCIR 625 lines, 50 images (EIA on request)
- Operating temperature from - 5° to + 45° C.
- Subject lighting by means of infrared LEDs
- Name-tag lighting through LEDs
- Built-in speech unit
- Removable terminal block
- Monitor call push-button.
- Output for control of lighting floodlight by relay type 170/101
- Lock release control with same timing as command from the monitor (1
second, not adjustable).
- Supply voltage from the bus.
- External dimensions: 80x120x25 mm.
CAMERA ADJUSTMENTS (ART. 68TC, 68TU)
On the camera rear side find the following adjustments:
External
Internal
volume
volume
CAMERA TERMINALS (TYPE 68TU, 68TC)
CL, M)
Connection for relay type 170/101 for additional floodlight.
It is activated for the time the camera is on.
CA, M)
Connection for additional lock push-button.
PA, M)
Connection for "open door" sensor. The sensor must be a nor-
mally open contact which closes when the door is open.
B1, B2) BUS line
S-, S+)
Output for electric lock supply voltage (12V
*
The panel supplies a current peak IT> 1A for 10 mS, followed by a hold
current I
= 200mA for the entire duration of the lock control.
M
EN
Camera activation
time
*
).
ENTRANCE PANEL/CAMERA
IDENTIDFICATION CODE.
If more cameras/entrance panels are installed on the building it is neces-
sary to identify the cameras with a different code. The identification code is
assigned by inserting the jumpers in the contacts as shown on the figure.
1st camera IT=0
ENTRANCE PANEL FOR VIDEO DOOR ENTRY SYSTEMS
Before installing equipment, choose location for camera entrance panel:
the camera shouid be protected from direct light (sun, car headlights, etc.)
as this may affect the quality of the picture, and may damage the camera.
This camera is equipped with Leds allowing perfect picture at max. one
metre distance. It is advisable to protect panel with some form of weath-
erproof shelter.
ENTRANCE
PANEL
FOR
INSTALLATION (see page 8-15)
OPERATING DwELL TIME
The monitor, camera, door lock and auxiliary services mut operate accord-
ing to the following intermittent cycles.
Monitor and camera activation cycle:
max. 90 seconds activated, 90 seconds deactivated
Door lock cycle:
max. 1 second activated, 5 seconds deactivated
Auxiliary service cycle:
max. 90 seconds activated, 90 seconds deactivated
CONNECTIONS
Videokit Type 68../R and 68../R2 in black and white.
The two connecting wires between power supply and monitor can be
inverted.
- The advised cable for the connection of the interphones/monitors with
the power supply and the entrance panel is type 732H (2x0,75 mm²
twisted pair) or 732I (2x1 mm² twisted pair). If the cable used is other
than the advised one we cannot guarantee what is written underneath.
- The installation is guaranted for a good operation with 100 m maximum
distance from the power supply to the monitor.
- In any case the maximum distance between the camera and the monitor
must not exceed 120 m.
- The electric lock connected to the installation must have a maximum of
1A power consumption with 12V voltage.
- Humming sounds or electrical discharges may affect the appliance good
operation.
Videokit type 68../RC and 68../RC2 (colour)
The two connecting wires between power supply and monitor can be
inverted.
- The advised cable for the connection of the interphones/monitors with
the power supply and the entrance panel is type 732H (2x0,75 mm²
twisted pair) or 732I (2x1 mm² twisted pair). If the cable used is other
than the advised one we cannot guarantee what is written underneath
- The installation is guaranted for a good operation with 50 m maximum
distance from the power supply to the monitor.
- The installation is guaranted for a good operation with 50 m maximum
distance from the power supply to the camera.
- In any case the maximum distance between the camera and the monitor
must not exceed 60 m.
- The electric lock connected to the installation must have a maximum of
1A power consumption with 12V voltage.
- Humming sounds or electrical discharges may affect the appliance good
operation.