3.5 AC Output
Inverter Output (IEC 146 class1), Continuous service (@ 400Vac)
Inverter Output (IEC 146 class 2), 150% overload for 60s (@ 400Vac)
P
mot (recommended motor output):
N
@ U
=230Vac; f
=default; IEC 146 class 1
LN
SW
@ U
=230Vac; f
=default; IEC 146 class 2
LN
SW
@ U
=230Vac; f
=default; IEC 146 class 1
LN
SW
@ U
=230Vac; f
=default; IEC 146 class 2
LN
SW
@ U
=400Vac; f
=default; IEC 146 class 1
LN
SW
@ U
=400Vac; f
=default; IEC 146 class 2
LN
SW
@ U
=460Vac; f
=default; IEC 146 class 1
LN
SW
@ U
=460Vac; f
=default; IEC 146 class 2
LN
SW
U
Max output voltage
2
f
Max output frequency
2
I
Rated output current:
2N
@ U
=230-400Vac; f
LN
SW
@ U
=230-400Vac; f
LN
SW
@ U
=460Vac; f
=default; IEC 146 class 1
LN
SW
@ U
=460Vac; f
=default; IEC 146 class 2
LN
SW
f
switching frequency (Default)
SW
f
switching frequency (Higher)
SW
Derating factor:
Voltage Factor K
at 460 Vac *
V
Voltage Factor K
at 460/480 Vac
V
Temp. Factor K
for ambient temperature
T
Switching frequency K
F
Switching frequency K
F
*: Linear shapes for K
, K
V
T
** On AVyL: Max output frequency refer to regulation in field oriented mode.
The output of the drive is ground fault and phase to phase output short protected.
Note! The connection of an external voltage to the output terminals of the drive is not permissible! It
is allowed to disconnect the motor from the drive output, after the drive has been disabled.
• Lift Drive System
Table 3.5.1: Output data
Type
= default; IEC 146 class 1
=default; IEC 146 class 2
, respectively in the ranges [400, 460] Vac, [40, 50]°C, (104, 122)°F.
2040
2055
[kVA]
6.5
8.5
[kVA]
5.9
7.7
[kW]
2.2
3
[kW]
2.2
3
[Hp]
3
4
[Hp]
3
4
[kW]
4
5.5
[kW]
4
5.5
[Hp]
5
7.5
[Hp]
5
7.5
AGy = 0.94 x U
[V]
AVy = 0.98 x U
[Hz]
[A]
9.6
12.6
[A]
8.7
11.5
[A]
8.3
11
[A]
7.6
10
[kHz]
[kHz]
AGy = 10/12/14/16, AVy = 12/16
AGy
0.87
AVy
0.87
0.96
0.8 @ 50°C (122°F)
AGy
0.7 for higher f
AVy
0.7 for f
SW
2075
3110
3150
12
16.8
22.4
10.9
15.3
20.3
4
5.5
7.5
4
5.5
7.5
5
7.5
10
5
7.5
10
7.5
11
15
7.5
11
15
10
15
20
10
15
20
(AC Input voltage),
LN
(AC Input voltage)
LN
420
17.7
24.8
33
16.1
22.5
30
15.4
23.1
29.7
14.0
21.0
27.0
8
0.93
0.9
0.87
0.93
0.9
sw
=16, 0.85 for f
=12
SW
tab_351