DANGER
Risk due to dust hazardous to health. Al-
ways use disposal clothing and P2 or higher
breath-safe masks while carrying out main-
tenance tasks (such as changing filters).
Exchanging the flat pleated filter
Illustration
Open filter door.
Remove filter frame.
Replace the flat pleated filter.
During placement, make sure that the
flat fold filter rests against all sides.
Dispose of the used flat-folded filter ac-
cording to the statutory provisions.
Insert filter frame.
Close the filter door, it must lock into
place.
Exchange the fleece filter bag
Illustration
Release and remove the suction head.
Pull the fleece filter bag towards the
rear.
Fold in the lock latch and tightly close
the fleece filter bag.
Dispose of the fleece filter bag accord-
ing to the local provisions.
Insert the new fleece filter bag.
Insert and lock the suction head.
Replace the disposal bag
Illustration
Release and remove the suction head.
Put the disposal bag over.
Tightly close the disposal bag with ca-
ble tie underneath the opening.
Remove disposal bag.
Dispose of the disposal bag according
to the local provisions.
Insert the new disposal bag.
Pull disposal bag over the container.
Make sure that the marking line is situ-
ated within the container and both ven-
tilation holes are positioned at the back
of the container.
Insert and lock the suction head.
20
Cleaning the electrodes
Release and remove the suction head.
Clean the electrodes with a brush.
Insert and lock the suction head.
Troubleshooting
DANGER
First pull out the plug from the mains before
carrying out any tasks on the machine.
Note: In case of a failure (e.g. filter break-
age) the appliance must be turned off im-
mediately. The failure must be remedied
before the appliance is put into operation
again.
Suction turbine does not run
Check the receptacle and the fuse of
the power supply.
Check the power cable, the power plug,
the electrodes and the receptacle of the
device.
Turn on the appliance.
Suction turbine turns off
Empty the container.
Suction turbine does not start again
after the container has been
Turn off the appliance and wait for 5 sec-
onds, turn it on again after 5 seconds.
Clean the electrodes as well as the
space between the electrodes with a
brush.
Suction capacity decreases
Remove blockages in the suction noz-
zle, suction tube, suction hose, or flat
pleated filter.
Replacing the full fleece filter bag.
Replace the filled disposal bag
Ensure the filter cover properly locks
into place.
Replace the flat pleated filter.
– 6
EN
emptied