Troubleshooting - Baier BSS 606L Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 50
DANGER
Risk due to dust hazardous to health. Al-
ways use disposal clothing and P2 or higher
breath-safe masks while carrying out main-
tenance tasks (such as changing filters).
Exchanging the flat pleated filter
Illustration
 Open filter door.
 Remove filter frame.
 Replace the flat pleated filter.
During placement, make sure that the
flat fold filter rests against all sides.
 Dispose of the used flat-folded filter ac-
cording to the statutory provisions.
 Insert filter frame.
 Close the filter door, it must lock into
place.
Exchange the fleece filter bag
Illustration
 Release and remove the suction head.
 Pull the fleece filter bag towards the
rear.
 Fold in the lock latch and tightly close
the fleece filter bag.
 Dispose of the fleece filter bag accord-
ing to the local provisions.
 Insert the new fleece filter bag.
 Insert and lock the suction head.
Replace the disposal bag
Illustration
 Release and remove the suction head.
 Put the disposal bag over.
 Tightly close the disposal bag with ca-
ble tie underneath the opening.
 Remove disposal bag.
 Dispose of the disposal bag according
to the local provisions.
 Insert the new disposal bag.
 Pull disposal bag over the container.
Make sure that the marking line is situ-
ated within the container and both ven-
tilation holes are positioned at the back
of the container.
 Insert and lock the suction head.
20
Cleaning the electrodes
 Release and remove the suction head.
 Clean the electrodes with a brush.
 Insert and lock the suction head.

Troubleshooting

DANGER
First pull out the plug from the mains before
carrying out any tasks on the machine.
Note: In case of a failure (e.g. filter break-
age) the appliance must be turned off im-
mediately. The failure must be remedied
before the appliance is put into operation
again.
Suction turbine does not run
 Check the receptacle and the fuse of
the power supply.
 Check the power cable, the power plug,
the electrodes and the receptacle of the
device.
 Turn on the appliance.
Suction turbine turns off
 Empty the container.
Suction turbine does not start again
after the container has been
 Turn off the appliance and wait for 5 sec-
onds, turn it on again after 5 seconds.
 Clean the electrodes as well as the
space between the electrodes with a
brush.
Suction capacity decreases
 Remove blockages in the suction noz-
zle, suction tube, suction hose, or flat
pleated filter.
 Replacing the full fleece filter bag.
 Replace the filled disposal bag
 Ensure the filter cover properly locks
into place.
 Replace the flat pleated filter.
– 6
EN
emptied

Publicidad

Tabla de contenido
loading

Tabla de contenido