Temperature Tables; Connection Data - Pepperl+Fuchs LHCR-51 Manual De Instrucciones

Ocultar thumbs Ver también para LHCR-51:
Tabla de contenido

Publicidad

LHCR-51, LHCS-51
SI00494O-C
EN

Temperature tables

Connection data

12
Device type LHCR-51
Mechanically fix probes which are more than 3 m (e. g. using guy ropes).
Device type LHCS-51
• Avoid electrostatic charging of the cable.
• Secure probes against swinging.
Intrinsic safety
The intrinsically safe input power circuit of the device is isolated from ground. The dielectric strength
is at least 500 V
.
rms
Service connection
Basic specification, feature output, option H
• For service operations a field communicator can be connected to the display socket.
• Comply with the safety instructions of the field communicator.
Device type LHCR-51
Type of protection
Temperature class Process temperature
Ex ic IIC T6...T4 Gc
T6
T4
• Do not exceed the max. ambient temperature at the housing.
• The process temperatures refer to the temperature at the rod.
Device type LHCS-51
Type of protection
Temperature class Process temperature
Ex ic IIC T6...T4 Gc
T6
T4
• Do not exceed the max. ambient temperature at the housing.
• The process temperatures refer to the temperature at the cable.
Basic specification, feature output, option H
Power supply
U
 45 V DC
i
I
 300 mA
i
P
 1 W
i
C
 10 nF
i
L
= 0
i
Basic specification, feature output, option P
Power supply
FISCO
U
 17.5 V DC
i
I
 500 mA
i
P
 5.5W
i
C
 5 nF
i
L
 10 H
i
Ambient temperature T
T
(housing)
p
 80 °C
-40 °C to +40 °C
 85 °C
-40 °C to +70 °C
Ambient temperature T
T
(housing)
p
 80 °C
-40 °C to +40 °C
 80 °C
-40 °C to +70 °C
Entity
U
 32 V DC
i
I
 250 mA
i
P
 1.2 W
i
C
 5 nF
i
L
 10 H
i
amb
amb

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Lhcs-51

Tabla de contenido