TECEfilo Electronic Urinal
Programming TECEfilo
After connecting to the power supply, do not stay in the sensor field for two
minutes. Then you can program the TECE electronics in the first 30 minutes.
Each configurable function is assigned a position.
Position
Function
1
Break function "off"
2
Break function "on"
3
Flush time 1 s
4
Flush time 2 s
5
Flush time 3 s
6
Flush time 4 s
7
Flush time 5 s
8
Flush time 6 s
9
Flush time 7 s
10
Flush time 8 s
11
Flush time 9 s
12
Flush time 10 s
13
Pre-flush "off"
14
Pre-flush 0.5 s
15
Pre-flush 1 s
16
Pre-flush 2 s
17
Hygiene/interval flush "off"
18
Hygiene/interval flush 24 hrs
19
Hygiene/interval flush 72 hrs
20
Hygiene/interval flush 168 hrs
21
Refill "off"
Refill "on" (refill for 2 s after
22
flushing for 2 s)
23
Sensor sensitivity "sensitive"
24
Sensor sensitivity "standard"
25
Hygiene flush volume small (5 s)
26
Hygiene flush volume medium (15 s)
27
Hygiene flush volume big (30 s)
28
Reset to factory settings
29
Urinal covers "off"
30
Urinal covers "on"
= Setting
During the programming phase, a red diode flashes in the centre
of the sensor field as soon as a person enters the area. This
diode acknowledges that the programming mode is activated. In
addition, it indicates the exact position of the programming key.
How to programme TECE electronics:
• Hold the programming key in front of the red diode
(see figure). The programming mode starts with a
quick series of short beeps.
• After the start-up phase you will hear a sequence of
the same distinct beep. Count the beeps until you
reach your desired function.
• Now remove the programming key. A long beep indi-
cates that the programming key has been removed.
Example: Setting the flushing time to three seconds
. . . .
Start
1
2
Hold the programming
Count the individual beeps until
key in front of the sensor
the desired position is reached
Flow characteristic curve:
Using the flow characteristic curve, the TECEfilo flush volume flow rate can be
read and set depending on the flow pressure as well as the flushing time:
0,6
0,5
0,4
0,3
0,2
1
2
3
Flow pressure (bar)
Example:
Mains pressure 4 bar → Flow rate 0.44 l/s → with 5 s flushing time ≜ 2.2 l
Adjustable functions:
Break function/Stadion function
When the break function is activated, the flushing time is automatically
reduced to one second following repeated flushes in short succession (= less
than two minutes). 45 minutes after the last economy flush, a standard flush is
triggered.
Cleaning function
Activating the cleaning function stops the urinal from flushing for ten minutes.
After this time a cleaning flush is automatically triggered and it returns to the
standard operating mode.
Activating the cleaning function:
Hold the programming key briefly in front of the sensor window until an
acknowledgement beep sounds.
The cleaning function can only be activated in standard mode and not during
the programming phase.
Hygiene/interval flush
Automatic flush actuation: 24, 72 or 168 hours after the last flush. The hygiene
flush volume can be set to small (5 s), medium (15 s) or large (30 s).