DAB E.SYBOX MINI 3 Instrucciones Para La Instalación Y El Mantenimiento página 73

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 358
1. Suction depth too
high.
Red: off
2. Suction pipe
Insufficient
White: on
clogged or diame-
delivery
Blue: off
ter insufficient.
3. Impeller or hydrau-
lic part clogged.
The pump
1. Leak in the
Red: off
starts with-
system.
White: on
out utility
2. Faulty non-return
Blue: off
request.
valve.
The water
pressure
Expansion vessel
Red: off
when turn-
empty (insufficient
White: on
ing on the
air pressure) or has
Blue: off
utility is not
broken diaphragm.
immediate.
When the
utility is
turned on
Air pressure in the ex-
Red: off
the flow
pansion vessel higher
White: on
falls to
than the system
Blue: off
zero before
starting pressure.
the pump
starts
1. As the suction depth increases
the hydraulic performance of
the product decreases. Check
whether the suction depth can
be reduced. Use a suction pipe
with a larger diameter (but never
smaller than 1").
2. Check the suction pipe, find the
cause of choking (obstruction,
dry bend, counterslope, ...) and
remove it.
3. Dismantle the system and
remove the obstructions (assis-
tance service).
1. Check the system, find and
eliminate the leak.
2. Service the non-return valve as
described in par. 9.3.
Check the air pressure in the ex-
pansion vessel. If water comes out
when checking, the vessel is bro-
ken: assistance service. Otherwise
restore the air pressure according to
the equation par. 1.2.
TCalibrate the expansion vessel
pressure or configure the parame-
ters SP and/or RP so as to satisfy
the equation par.1.2.
1. No water.
2. Pump not primed.
The display
Red: on
3. Setpoint not
shows
White: on
reachable with the
BL
Blue: off
set RM value
The display
Red: on
1. Faulty pressure
shows
White: on
sensor.
BP1
Blue: off
The display
Red: on
shows
White: on
1. Faulty pressure
BP2
Blue: off
sensor.
1. Excessive absorp-
The display
Red: on
tion.
shows
White: on
2. Pump blocked.
OC
Blue: off
1. Supply voltage
The display
Red: on
too low.
shows
White: on
2. Excessive drop in
PB
Blue: off
voltage on the line.
GB
ENGLISH
1-2. Prime the pump and check
whether there is air in the pipe.
Check whether the suction or any
filters are blocked.
3. Set a RM value that allows the
setpoint to be reached.
1. Contact the assistance centre.
1. Contact the assistance centre.
1. Fluid too dense. Do not use
the pump for fluids other than
water.
2. Contact the assistance centre.
1. Check the presence of the
correct supply voltage.
2. Check the section of the power
supply cables.
70

Publicidad

Tabla de contenido
loading

Tabla de contenido