DESCRIPTION
The numbers in the text refer to the diagrams on
pages 2-3.
1. Boiler carrying handle
2. Boiler tank
3. Water level indication
4. Hose
5. hose connector
6. Steam plate
7. Filler cap
8. Power cable
3. ASSEMBLY
Fitting the hose (fig. A and B)
• Screw one end of the hose (4) to the hose con-
nector (5) on the boiler tank (2).
• Screw the other end of the hose (4) to the
steam plate (6).
• Check that the hose has been connected
properly.
Initial filling of the boiler reservoir (fig. C)
Warning! Make sure that the appliance is
unplugged.
• Unscrew and remove the filler cap (7).
Note: When filling the boiler, use clean tap
water only.
• Fill the boiler tank (2) with water.
Do not overfill the tank past the MAX indicator
(maximum 4.5 litres) see fig. D.
• Place the boiler filler cap (7) back, do not over-
tighten.
• Place the steam plate (6) in a bucket before
starting the machine, never lay the steaming
plate flat on a surface always on its back see
fig. H.
Power cable (fig. E)
• Plug the connector of the power cable (8) in to
the machine.
• Plug the mains plug of the power cable (8) into
the power supply.
• The machine will automatically start working
when plugged in correctly.
TIP! Fill the machine with warm tap water to shor-
ten the warm-up time.
WWW.VONROC.COM
4. OPERATION
Steam is hot! The unit is designed for safe,
fast removal of wallpaper but please be aware
that steam is produced at 100°C so be careful,
wear protective clothing and protect your
hands with heat resistant gloves or mitts.
Please note: When waiting for the steam to appear
and when putting the steam plate down during use,
always place it on its back. This will prevent the
steam coming into contact with anything that may
be damaged. Some water may spit from the steam
plate. However, this is quite normal and will not
affect the performance of your unit.
Reaching temperature
• Depending upon the temperature of the water
used to fill the reservoir (3), the appliance will
take between 6 and 11 minutes to start produ-
cing steam.
Refilling the boiler reservoir (fig. C)
WARNING! Refill boiler every 75 minutes. Do
not go under the minimum level (fig. D). Do
not re-fill while the boiler is pressurised!
• Disconnect the appliance from the mains supply.
• Wait at least 2 minutes for the water to cool and
the pres¬sure to decrease before removing the
boiler filler cap (7).
The filler cap may be hot during use and
during the cool down period.
• Unscrew and remove the filler cap (7).
• Fill the boiler reservoir (2) with clean tap water.
Do not overfill the reservoir past the MAX indi-
cator (maximum 4.5 litres) see fig. D.
• Replace the boiler filler cap (7), do not overtigh-
ten.
• Plug the mains plug into the power supply.
• An additional feature is the safety valve. Should
excess pressure build up inside the water tank,
steam will automatically be released through
the safety valve. This may be caused by the
hose being shut off by standing on it or by
placing a ladder on it.
• However, should the safety valve not operate for
any reason, send the unit back for reparation.