4° Checking manoeuvre direction, force adjustment and slowing down when approaching
WE REPEAT: If the gate opens to the left reverse V and W and LSO with LSC.
Note: In this phase the gate moves only by constantly pressing the PROG button and is the step-by-step type which means that
each time the PROG button is pressed we have an open-stop-close-stop-open ... manoeuvre.
To confirm that the configuration is good check the LEDs as described below.
a) Set the DIP 1-2-3-4-5-6-8-10-12 micro switches on OFF and DIP 7-9-11 on ON.
b) Set DIP 1 on ON (the DL1 LED flashes quickly)
c) Set the "TORQUE" force adjustment trimmer on minimum
d) Press and hold the PROG button (the green LED turns on and the gate opens)
e) Gradually increase "TORQUE" force only if necessary (WARNING: too much force can be dangerous for the users)
f) After 10 seconds the motor slows to a speed that is adjusted with the "LOW SPEED" trimmer.
g) At the end of opening, the limit switch is pressed by the cam and stops the motor (the DL3 and "OPEN" LEDs turn off).
h) Release the PROG button.
i) Press and hold the PROG button again (the red "CLOSE" LED turns on and the gate starts closing)
j) After 10 seconds the motor slows down. The limit switch stops the motor when the gate is completely closed (DL4 and
"CLOSE" turn off)
k) Release the PROG button and press PROG again to open the gate slightly and free the end-of-closing limit switch.
l) Put DIP 1 back on OFF and go to step 5.
5° Programming working and waiting times before having automatic closing.
IMPORTANT: Jumper between COM-PHOT and COM-EDGE if the safety devices are not installed. LEDs DL7 and DL8 must be on.
If a LED is off it indicates a safety device failure or no connection and gate movement is blocked.
a) Set DIP 2 on ON (the DL1 LED flashes slowly)
b) Press the PROG button briefly (the gate closes, it stops when it comes up against the stop, it waits 2 seconds and then opens automatically, stopping against the end-of-opening limit switch).
Once the gate has completed the opening manoeuvre the control panel starts counting the waiting time before the gate starts closing automatically.
Note: Even if the automatic closing function is not active (DIP 3 OFF), it must still be memorized.
c) Wait for the length of time wanted and then press the PROG to store the waiting time and start the gate closing.
d) The gate is closed. DL1 stops flashing. The times are stored. Put DIP 2 back on OFF.
6a° Programming the remote control (for K-CRX)
1 - Put DIP 1 on ON and then DIP 2 on ON => the DL1 LED flashes for 10 seconds.
2 - Press the key on the remote (normally channel A) within the 10 seconds. If the remote is stored correctly the green DL2 LED flashes once.
3 - Code programming time is renewed automatically so the next remote control can be stored.
4 - To end programming wait 10 seconds or press the PROG button briefly => the DL1 LED stops flashing.
5 - Put DIP 1 back on OFF and DIP 2 on OFF.
6b° Programming the remote control (for K)
Plug an ACG5051 radio receiver onto connector J5 (this lets you control the electronic panel directly with the first channel of the remote).
Connect the second relay R2 of the radio receiver to COM/PED so the pedestrian opening or other device can be radio controlled.
Action
Press briefly the small button P on the receiver
Press key A on the remote control for 1.5 seconds
Press briefly the small button P on the receiver
Press key B on the remote control for 1.5 seconds
Let DL2 flash 10 times or press P on the receiver to exit programming
7° Customising the configuration
The configuration can be modified by moving the various microswitches
Microswitches ON
DIP3
Automatic closing activated
DIP4
Photocells active only in closing
DIP5
Pre-flashing for 3 seconds
DIP6
Step-by-step command
DIP7
Electronic brake activated
DIP8
Slowing down not activated
DIP9
Gradual start activated
DIP10
safety strip self-test activated
DIP11
K500
DIP12
-
IMPORTANT: The system must comply with all the standards and Directives currently in force.
LED confirm
DL1 and DL2 flash
DL1 flashes
DL2 flashes once
DL2 flashes
DL1 flashes once
Microswitches OFF
Automatic closing not activated
Photocells active all the time
Motor and flasher start together
The command has no effect in opening
Electronic brake not activated
Slowing down activated
gradual start not activated
safety strip self-test not activated
-
K500
Reaction
Remarks
release P
go to step 2°
does not transmit
go to step 3°
release P
go to step 4°
does not transmit
Finished
A
A
A
A
A
A