Specific Operating Instructions
1
2
3
a.) Installation
Fastening holes (3) are provided for wall mounting. The unit must be mounted against a vertical, fireproof wall with the
connections at the bottom, see above picture, left part. For outside installation the device must also be protected against
exposure to rain and direct sunlight.
b.) Functional description of the unit
Put unit into service WITHOUT fence system. Random values are shown on the displays and the indicator lights start
flashing green or red. The values are not relevant as long as the fence system is not connected. The unit is ready for
use.
If after inserting the unit no values are shown on the displays or the indicator lights do not flash, check the supply voltage
and/or the power cable. If no fault is found, have the unit checked by a technician.
c.) Functional description of the appliance with CONNECTED fence system
Display
1,1
≤3,5
≥1,1
Fence systems may be operated independent of each other at the fence connections (5 or 6).
The measured value indicated in the display (1) and the associated indicator light are nevertheless only capable of
displaying the exit exactly with maximum energy (6). If the indicator light flashes faster than once per second, the unit
must be disconnected at once and checked by a technician before it can be used again.
Any user of electric fence systems is legally indebted to control the fence-appliance and the fence system regularly, in
accordance with the conditions of use, at least once per day.
visual check of the appliance and the fence system
-
-
measurement of the minimum voltage of 2500V at each point of the fence
This equipment carries a 3-year warranty in accordance with our Warranty Terms & Conditions!
Please see the attached Operating Instructions for safety tips, earthing, commissioning, warranty terms and
conditions and potential sources of fault!
SERVICE Addresses:
Please contact your specialist dealer
3
4
6
5
Mains plug used as ON / OFF!
Connection to 230 V ~!
This energizer shall not be used as an animal
trainer (inside a barn).
Output
voltage
Earth voltage
Fence NOK; output voltage ≤ 3.5 kV
Remedy:
See fault finding in enclosed instruction manual (Figure 2; p.5)
Earth NOK; voltage on earth electrode ≥ 1,1 kV
Remedy:
See fault finding in enclosed instruction manual (Figure 2; p.5);
IDEAL
6.0 – 10.0 kV; indicator
light
flashes green
0.0 kV;
indicator light
flashes green
3
Output voltage in kV
1
LCD display with
indicator light
Earth voltage in kV
2
LCD display with
indicator light
Fastening holes
3
4
Earth connection
Fence connection
5
with reduced energy
Fence connection
6
with maximum energy
OK
> 3.5 kV
(e.g. 4kV = 4000V)
indicator light flashes
green
< 1.1 kV;
indicator light flashes
green
-EN-
CHECK
≤ 3.5 kV
indicator light
flashes red
≥ 1.1 kV;
indicator light
flashes red
Version : 2019.1