The display shows
"thermal fuse tripped"
the display shows "temperature
sensor interruption"
Insufficient water
in the steamer
(audible alarm)
Failed data
communication
(control panel)
Unknown error
the heater protection device (op-
tional) was activated
the alarm button (optional) was
pressed
incorrect connection or faulty sensor
incorrect connection or faulty sensor
the steamer tank is almost empty
(an audible alarm will sound)
if an automatic water filling device is
installed, check that the tap on the
supply pipe is open and/or the water
system is functioning correctly.
defective connection between the
control panel and the electrical box
defective connection between the
control panel and the electrical box
48
- Make sure no object was left over the heater
protection
- After checking the cause, deactivate the but-
ton by turning it to release it.
- Contact an authorized Jacuzzi® service centre.
- Contact an authorized Jacuzzi® service centre.
- Fill the tank as described in the "Preliminary
operations" chapter.
Before adding water, turn off the
heater and wait for the temperature
of the heating element and the heater
cover to decrease to prevent the for-
mation of dangerous steam sprays.
- Try turning the main switch off and back
on; if the fault persists contact an authorized
Jacuzzi® Service Centre
- Try turning the main switch off and back
on; if the fault persists contact an authorized
Jacuzzi® Service Centre