Operating Instructions SATA FDG
EN
[2‑4] / [3‑4] / [8‑6] / [9‑5] .
■ Undo the toggle screw [1‑10] / [7‑13] .
■ Open the clamp [1‑7] / [7‑11] outwards.
■ Take the tank cover [1‑5] / [7‑8] off the pressure tank [1‑8] / [7‑10].
■ Clean the pressure tank with a suitable cleaning agent (see chap-
ter 12).
■ Fill the material pressure tank with material.
Close the material pressure tank
■ Mount the tank cover [1‑5] / [7‑8] on the material pressure tank
[1‑8] / [7‑10].
■ Close the clamp [1‑7] / [7‑11] inwards and position the toggle screw
[1‑10] / [7‑13] on the inside of the cover bead.
■ Tighten the toggle screw hand-tight.
■ Connect the agitator with the power / compressed air circuit.
■ Connect the material pressure tank with the compressed air circuit and
adjust the pressure within the permitted range.
■ Connect the material and spraying air supply (see chapter 10.2).
11. Maintenance and repairs
The following chapter describes the procedures involved for maintaining
and repairing the material pressure tank.
11.1. Check the safety valve
Risk of injury from defective safety valve
A defective safety valve fails to vent the material pressure tank properly
and it can explode.
→ Check the safety valve regularly. If no air is discharged at the safety
valve, stop the pressure tank immediately and replace the safety valve.
The safety valve [2‑3] / [3‑3] / [8‑10] / [9‑10] may only be checked by au-
thorised staff with adequate know-how in this field.
■ Close the bleeder valve.
■ Pressurise the material pressure tank within the permitted range.
■ Check the safety valve by turning to the left. Air must be heard to be
discharged.
■ Close the safety valve again after it has been checked.
11.2. Check the tank cover seal
■ Open the material pressure tank (see chapter 10.4).