Electric agitator
MU-...E(G)1500...
Operating instructions
4.5 Functional description
4.5.1 General
The mixing unit is used to homogenise and agitate the mixture. The agotator shaft is operated clockwise and
vertically in order to prevent the mixing element from coming loose and to align the mixing direction to the tank.
The agitator must be operated in a vertical position in order to prevent a shifting of the exccentricity.
The mixing units are not complete machines.
4.5.2 Drive motor
The unit is driven by an AC motor.
(For information on how to connect the drive motor, see chapter 8 / for motor data, see chapter 5.2)
4.6 Accessories
4.6.1 Tie-bar
The tie-bar (total length 1200mm) for the MU-200/300/500E1500EB.1 can be attached to IBC containers with
tubular steel frames and open containers (up to 1000L) with an outer minimum diameter of 600mm to a maximum
diameter of 1150mm (provide mounting eye) and then braced using the tighteners. The electric agitator is put on
wing nuts that can be freely moved in the rail and then fixed using the M8 hexagonal screws, moved, moved into
the desired position and tightened (see the example below).
NOTE!
Wing nut
Tightener
46
www.sera-web.com
In case of round containers, ensure the exccentric position of the electric agita-
tor because of the formation of swirls (excentricity = 0.25 to 0.33 x diameter of
the container).
Hexagonal screws
Rail
Subject to technical modifications!
Tie-bar