Electric agitator
MU-...E(G)1500...
Operating instructions

7.1 Assembly

Install the mixing unit vertically into the tank.
The mixing unit may only be installed into an empty tank.
The position for the tank will be marked using the boring template (see last page) and is then bored according
to the geometry specifications. Remove the chips from the tank.
In case of the PE encased design, wind the mixing element clockwise with PTFE tape 8 to 10 times.
2 people are required to assemble the electric mixing unit.
One person holds the mixing unit at the flange and the shaft
without the mixing element is inserted through the borehole in
the centre.
The shaft end is tilted laterally towards the tank opening and
the second person screws on the mixing element onto the
shaft.
NOTE!
The mixing unit is fixed to the tank using the screw set.
Observe the required screw tighening torques:

7.2 Disassembly

Observe safety data sheets and warning notices for the stirred medium.
During operation, the agitator shaft may become hot at the flange. Let it cool after operation.
Loosen the screw connection with the tank.
2 people are required for the disassembly of the mixing unit.
One person holds the mixing unit at the flange (motor housing). The shaft end is tilted laterally towards the
tank opening and the second person unscrews the mixing element from the shaft.
The mixing unit is removed from the tank.
50
www.sera-web.com
Do not leave the mixing unit
hanging in the tank! /
Do not load the shaft in a way that
will cause it to bend!
Screws
M6
M8
M10
Subject to technical modifications!
Tightening torque
Nm
3,5
4,0
6,0
TA 452 Rev. 4