ADJUSTMENT
STEP
1
Adjust
the
UP and
DOWN
Travel
Limits
Limit adjustment settings regulate the points at which
the door will stop when moving up or down.
To operate the opener, press the Door Control push
button. Run the opener through a complete travel
cycle.
•
Does the door open and close completely?
•
Does the door stay closed and not reverse
unintentionally
when fully closed?
If your door passes both of these tests, no limit
adjustments are necessary unless the reversing test
fails (see Adjustment Step 4, page 30).
Adjustment procedures are outlined below. Read the
procedures carefully before proceeding to
Adjustment Step 2. Use a screwdriver to make limit
adjustments. Run the opener through
a complete
travel cycle after each adjustment.
NOTE: Repeated operation of the opener during
adjustment procedures may cause the motor to
overheat and shut off. Simply wait 15 minutes and try
again.
NOTE: If anything interferes with the door's upward
travel, it will stop. If anything interferes with the
door's downward travel (including binding or
unbalanced doors), it will reverse.
HOW AND WHEN TO ADJUST THE LIMITS
• If the door does not open completely but
opens at least five feet:
Increase up travel. Turn the UP limit adjustment
screw clockwise. One turn equals 2" of travel.
•
If door does not open at least 5 feet:
Adjust the UP (open) force as explained in
Adjustment Step 2.
•
ff the door does not close completely:
Increase down travel. Turn the down limit
adjustment screw counterclockwise.
One turn
equals 2" of travel.
If door still won't close completely, try lengthening
the door arm (page 26) and decreasing the down
limit.
If the opener reverses in fully closed position:
Decrease down travel. Turn the down limit
adjustment screw clockwise. One turn equals 2"
of travel.
Without a properly installed safety reversal system,
persons (particularly small children) could be
SERIOUSLYINJUREDor KILLED by a closing garage
door.
• Incorrect adjustment of garage door travel limits will
interfere with proper operation of safety reversal
system.
• If one control (force or travel limits) is adjusted, the
other control may also need adjustment.
• After any adjustments are made, the safety reversal
system MUST be tested. Door MUST reverse on
contact with one-inch high object (or 2x4 laid flat) on
floor.
To prevent damageto vehicles, be sure fully open door
provides adequate clearance.
jo
_1 17
L
I /_0
0
0
0
Adjustment
Left Side Panel
Screws
f_+_djust
UP Travel
+'_
Adjust DOWN Travel
If the door reverses when closing and there is
no visible interference to travel cycle:
If the opener lights are flashing, the Safety
Reversing Sensors are either not installed,
misaligned, or obstructed. See Troubleshooting,
page 22.
Test the door for binding: Pull the emergency
release handle. Manually open and close the door.
If the door is binding, call for professional garage
door service. If the door is not binding or
unbalanced, adjust the DOWN (close) force. See
Adjustment Step 2.
28