Function / Operation; Accessories (Optional) - STEINEL PROFESSIONAL NightMatic 5000-3 DALI Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 23
• Switch ON power supply�
• Set functions. (➔ "6� Funtion")
• Fit designer trim.
6� Function / operation
Factory settings
Twilight level:
1000 lux
Night economy mode:
OFF
Main light level:
80%
Setting for morning hours: light ON in the morning
Remote controls RC 5, RC 8 or Smart Remote can be used for resetting to the factory
settings.
Constant light
Provides a constant level of brightness. The sensor measures the prevailing level
of daylight and activates sufficient artificial light to achieve the required level of
brightness. As daylight changes, the added artificial lighting component is adjusted.
Constant-lighting control can be activated / deactivated by RC 8 remote control and
Smart Remote.
Twilight setting (Fig� 6�1)
On actuating the control dial, the sensor is in programming mode.
This means:
– The light connected always goes out.
– The sensor function is deactivated.
The settings may be altered as often as you wish. The last setting will remain stored
in the memory in the event of power failure.
Important: while setting the light sensor, do not cover it or shade it with your own
shadow
Dazzle guard
This product is equipped with an integrated dazzle guard. A drastic change in ambi-
ent brightness does not immediately switch OFF the sensor. The change in ambient
brightness must last for longer than 1 second.
Night economy mode setting
The load connected can be switched OFF automatically at night to save even more
electricity. The night economy mode always ends in the early hours of the morning
between approx. 4 and 5 a.m. The economy time can be infinitely adjusted at the
control inside the unit from 0 to approx. 7 hours. The control is divided into two
sections. If the control is set to the left-hand scale side, the load will be switched
18
OFF between 4 and 5 a.m. after the night economy time elapses. If the control is set
to the right-hand scale side, the load will be switched OFF after the night economy
time elapses and ON again when it gets dark. Wherever possible, avoid setting the
control to the middle position. The electronic system does not have a clock. All times
are computed by the microprocessor on the basis of light levels at twilight. Seasonal
changes in light levels are identified automatically and taken into account.
Important:
Setting for morning hours
Control dial set to OFF means light stays OFF in the morning.
Control dial set to ON means light switches ON at dawn and OFF when it is light
enough.
Long night economy mode
OFF in the morning
Mid-range night economy
mode OFF in the morning
No night economy mode
OFF in the morning
LED function
– Remote control: LED flashes approx. 10 times per second
– Normal mode: LED stays OFF
Note:
After putting the unit into operation and defining the twilight setting for the first time,
the light stays ON all through the first night until the morning so that it can determine
light levels at dusk and dawn.
7� Accessories (optional)
User remote control RC 5 EAN 4007841 592806
Additional functions RC 5
– Light ON/OFF 4 h
– User reset
– 100 h burn in, 4 h light ON press for ≥ 5 s
– DIM1 - / DIM1 +
Note - constant light active: cannot be dimmed
– Save scene 1
– Activate scene 1
– Save scene 2
– Activate scene 2
Long night economy mode
ON in the morning
Mid-range night economy
mode ON in the morning
No night economy mode
ON in the morning
19

Publicidad

Tabla de contenido
loading

Tabla de contenido