GB
1� About this document
– Please read carefully and keep in a safe place.
– Under copyright.
Reproduction either in whole or in part only with our consent.
– Subject to change in the interest of technical progress.
Symbols
!
Hazard warning!
Reference to other information in the document�
...
2� General safety precautions
!
Disconnect the power supply before attempting any work on the sensor�
• During installation, the electric power cable to be connected must not be live.
Therefore, switch off the power first and use a voltage tester to make sure the
wiring is off-circuit.
• Installing the sensor involves work on the mains power supply. This work must
therefore be carried out professionally in accordance with national wiring regula-
tions and electrical operating conditions. (e.g.: DE-VDE 0100, AT-ÖVE-EN 1,
CH-SEV 1000)
3� NightMatic 5000-3 DALI
Proper use
– The NightMatic 5000-3 is suitable for ceiling and wall mounting indoors and
outdoors.
The NightMatic 5000-3 DALI photo-cell controller measures ambient brightness and
automatically switches the light ON at dusk and automatically switches it OFF again in
line with various setting options. The NightMatic 5000-3 comes with new diffuse light
measurement. This detects the level of light in its entire surrounding, taking better
measurements than conventional light sensors.
Package contents for surface-mounted installation (Fig� 3�1)
16
Product components (Fig� 3�2)
A Load module
B Designer trim
C Sensor module
Product dimensions (Fig� 3�3)
4� Electrical installation
The mounting location should be selected so that daylight is able to fall onto the light
sensor. An optional corner wall mount (product no. 648015 black or 035174 white) is
available for mounting the NightMatic 5000-3 DALI.
The supply lead consist of three wires:
L
= phase conductor (usually black, brown or grey)
N = neutral conductor (usually blue)
PE = protective-earth conductor (green/yellow)
Wiring example (Fig� 4�1)
Note on manual override function:
A power switch for switching the light ON and OFF can be installed in the mains sup-
ply lead. This is a prerequisite for the manual override function. (➔ "6� Function")
If the rubber seal is damaged, the cable entry openings must be sealed with an
M 16 or M 20 (at least IP 54) double seal cable gland.
For mounting on the wall, a condensation water drainage hole (Ø 5 mm drill bit) is
marked next to the rubber seal. This must be opened if necessary. (Fig� 5�2)
5� Mounting
• Check all components for damage.
• Do not use the product if it is damaged.
• Choose an appropriate site to install the product. Make sure that no lamp is shining
light directly on the sensor.
Installation procedure (Fig� 5�1 - Fig� 5�2)
• Switch OFF power supply.
• Detach designer trim from sensor module.
• Disconnect sensor module from the load module.
• Connect to mains power supply. (Fig� 5�3)
• Insert fastening screw and mount load module
• Fit sensor and load module together and screw into place
17