Description
1.9.5
Temperature Sensors
Order Number
44.00-T50 (Temperature sensor) (L=50 mm/1.97")
44.00-T100 (Temperature sensor) (L=100 mm/3.94")
44.00-T150 (Temperature sensor) (L=150 mm/5.91")
A calibration table is provided for every temperature sensor, which shows its deviation from the m&h reference
measurement device. In order to achieve an accuracy level of within ±1°C, the measurement values taken with
the temperature sensor must be calculated using the corresponding correction values! The achievable resolution
is:
•
±0.1°C => for analog/digital machine inputs
•
±1°C => for analog/analog machine inputs
Fig. 8
Temperature sensor calibration table
64
Illustration
INFORMATION
IRP25.50