4 Installation
See Fig. A at the front of these operating and maintenance instructions.
4.1 Assembling the Accessories
a) Insert the lance hose (11) on the water gun (8) and tighten.
b) Mount the accessory support (26) on the handlebar (30); mount the knob and the lever (13) on the
hose reel (6) (only PW 160C - PW 170C - IP 1700S).
c) Mount the hose (25) between the hose reel and the water cleaner, by tightening the two fast coupling
connectors; unroll the hose quantity (7) that is necessary by rotating the hose reel by means of the knob
(13) (only PW 160C - PW 170C - IP 1700S).
d) Unroll the high-pressure hose (7), connect the fast coupling connector to the water outlet connector
(5), screw and tighten (only PW 160 - IP 1600).
e) Screw the end of the high-pressure pipe (7) (side without fast coupling for PW 160 - IP 1600) on the
water gun thread (8) and tighten with two 17-mm box wrenches (not supplied).
f) Insert the water suction filter (15) into the water suction connector (14) and tighten it on the water
inlet connector of the water cleaner.
4.2 Controls and Connection to the Mains Water Supply
CAUTION
• The water supply must be able to guarantee the adequate delivery of water flow to the high pressure
cleaner; refer to the table of technical specifications.
In case of doubt, contact a Skilled Technician.
• Do not supply the water cleaner with water at a temperature in excess of 50°C/122°F or below 5°C/41°F.
• The pressure of the water supply must not be in excess of 8 bar/116 psi.
• Do not operate the high pressure cleaner with a priming depth in excess of 0 m / 0 ft.
• Do not operate the high pressure cleaner if it is not connected to a water supply.
• Do not supply the high pressure cleaner with salt water or water containing impurities. In this event,
run the high pressure cleaner for a few minutes with clean water.
WARNING
• Follow current regulations for connection to the mains water supply in the country where the water cleaner
is installed.
4.3 Checks and Connection to the Mains Electricity Supply
WARNING
• A Skilled Technician must check that the electrical supply complies with the data indicated on the
identification label (18) on the high pressure cleaner. It is especially important that the supply voltage
does not differ more than +-5% from that indicated on the label.
• All connections to mains electricity must be carried out by a Qualified Eletrician according to IEC 60364-1
regulations or the equivalent standard in the country where the high pressure cleaner is to be used. It is
especially important that the current outlet where the high pressure cleaner is connected is provided with
an earth conductor and a suitable fuse (according to the size indicated on the identification label and
in the table of technical specifications), and must be protected by a magneto-thermal differential circuit
breaker, whose sensitivity is not in excess of 30 mA.
• If the power supply cable is too short, an extension cord can be used provided it is not longer than 10 m
/ 32.8 ft, the section of the wires is at least 1.5mm² and the plug and the socket are waterproof. Contact
a Qualified Eletrician so that all these requirements are followed.
The use of unsuitable extension cords can be dangerous.
5 Operation
WARNING
• The high pressure cleaner must be used with care and attention. It is your responsibility to make sure that
any infrequent users have read these instructions and are acquainted with the operation of the water
cleaner; otherwise do not allow others to use the high pressure cleaner. Water cleaners must not be used
20