Danfoss DWH 200 Instalación/Mantenimiento página 8

Tabla de contenido

Publicidad

1.4.5
Unvented package installation, DWH 200, DWH 300
Return line
heating system
Supply line
heating system
Figure 5.
The principal installation solution of the unvented package on a DWH.
Position
Name
1
Factory fitted combined Temperature and Pressure Relief Valve
2
Expansion Vessel
3
Flexible hose
5
Unvented manifold assembly: Pressure Reducing Valve, Safety Relief Valve,
Non-return Valve
6
Shut-off Valve
7
Double Check Valve with Shut-off Valve
8
Flexible hose
9
Safety Relief Valve
10
Expansion Vessel Heating System
11
Strainer
*
) The water heater tank in DWH is factory fitted with a Temperature and Pressure Relief Valve. The connec-
tion from this valve must not be used for other purposes other than discharge pipe connection. Please see
next page for Discharge Pipe Arrangement.
E
Note! No valve should be fitted between the safety relief valve and the storage cylinder.
8
10
11
DWH 200
Heat pump
DWH 300
HW to
house
9
1
*
VMBNB72J
CW to
6
house
8
6
7
5
6
3
Unvented manifold assembly
(see figure 1)
3
2
CW