7. CONNECTION TO THE MAINS
1.
Ensure that mains voltage and frequency are the same as those stated on the rating plate
2
to the appliance. . Ensure that the supply socket has the following characteristics:
earthed.
b)
It is appropriate for the nominal current In, as set out on the rating plate.
the IEC regulations: - magnetothermal differential switch (a.k.a. ground fault interrupter) with In =
nominal value as stated on the rating plate; - Differential with Id sensitivity = 30 mA
is no danger of explosion (AD) in the room. . The connecting cable to the appliance is H05 VVF,
designed for internal use. . Connect the plug (do not use three-way adapters and reduction adapters).
N.B.
If during transport or storage the appliance has been placed by mistake in a horizontal position or
has been turned upside down, leave for at least three hours in the correct position before switching on the
6
power supply. . Press the refrigeration switch (the green light will come on) (see figure 6).
8. CONTROLS
The appliance features adjustment controls on the side panel. . To adjust the internal temperature, turn
2
the thermostat. . Switch on internal lights (see figure 7).
9. CHECKING CORRECT OPERATION
MAKE SURE THAT: 1
. The appliance is plugged in. . The refrigeration unit switch is switched on with
3.
the green light on.
The door is completely closed. . The inside temperature is suited to the stored
5
goods. . The cabinet is not exposed to direct sunlight or high-powered lamps.
does not exceed that in which the appliance is designed to work normally, i.e. +25°C, R.H.60% (climatic
7.
class 3).
There is adequate airflow to the motor compartment. . The internal compartment is correctly
loaded, without overloading the shelves (max. 5 kg each) and leaving adequate space for the correct
circulation of cold air.
10. INTERNAL CLEANING (EVERY 15 DAYS)
1.
Switch off the appliance.
4
defrost for about 1 hour. . Wipe the internal surfaces of the appliance with a sponge dipped in water with
a little sodium bicarbonate. Pay attention to the sharp evaporator fins. Dry with care.
11. REPLACING THE INTERNAL LIGHT
1.
Switch off the appliance.
3.
Detach the transparent protection.
5
. Extract the lamp and replace it. . Refit the other parts in reverse order (see figure 8).
12. REPLACING THE DOOR'S MAGNETIC GASKET
1.
2.
Open the door.
Grasp the magnetic seal and remove it from the door frame.
and press all around to ensure it is firmly in place (see figure 9).
13. REPLACING A GLASS PANEL
1.
Switch off the appliance. . Undo the screws attaching the door hinges to the frame and remove the
3
door. . Unscrew both the screws to the upper and lower angle mountings at the doorjamb. . Unscrew
the fixing screws from the inside rear angles, at the top and the bottom.
6
sliding sideways. . Remove the glass panel, sliding sideways. . Replace with new glass panel (see
figure 10).
Operator's guide
4
5
2.
Open the door and remove the refrigerated goods.
2.
Remove the side protection from the lamp, by pulling sideways.
4.
Rotate the fluorescent tube until it clicks (approximately 90°).
6
2
1
2
4
8
5.
Remove the corner mountings,
7
7
(A)
attached
a)
it is properly
c)
It complies with
3
. . Ensure that there
6.
The room temperature
3.
Let the evaporator
3.
Insert the new seal
4
I
UK
D
E
F
NL
P
S
DK
FIN
B
GR
CZ
EE
LV
LT
H
M
PL
SK
SLO