2.9
Assembly
These instructions are not to be viewed as assembly instructions; hints and tips are
provided only for trained expert installers. Suitable clothing and personal protection must
be worn for the following work.
Incorrect installation and settings lead to exclusion of liability and warranty.
Partly pre-assembled machines must be checked, introduced and approved by a competent person before
commissioning.
Machine assembly must be carried out by a qualified and competent person.
2.9.1. Foundation properties
When assembling on floor coverings, check their load-bearing capacity. A construction expert should be
consulted for inspection when mounting on floor coverings.
Foundation dimensions in mm
Length
Length of machine
+ 500 mm
® Copyright ATH-Heinl GmbH & Co. KG, All rights reserved / Misprints and technical changes reserved / As of: 2020-03
Width
Width of machine
+ 500 mm
Manufacturer ATH-Heinl GmbH & CO.KG
Concrete grade
B25 according to DIN
1045
- 19 -
Floor load
425 kg / cm²
Floor
Ferroconcrete
Electro-soldered
grid
Gravel