Setup Tool
Title
❖
•
Enter the title of the Email.
Message
❖
•
Enter the contents of the Email. An alarm image is
attached to the Email as an attached file.
Test
❖
•
To test SMTP transmission, Click [Test] button.
Connect to the configured SMTP server and
conduct image transmission test automatically.
When the SMTP server connection and
transmission tests are complete, the <Verified>
message will be displayed.
If the test fails, an error message appears. In this
case, check the SMTP server status and the
configured settings once again.
alarM IMaGe SeTuP
Transfer Mode
❖
•
You can select a method to send an alarm image
from the <FTP>, <E-Mail>.
<FTP Transfer>: The image is sent to the specified
FTP address.
<E-Mail Transfer>: The image is sent to the
specified Email address.
Transferred Image Naming Setup
❖
•
You can set the file name of an alarm image to
be sent when an alarm is generated or during the
scheduled transfer.
Pre/Post alarm Image
❖
•
You can determine which of previous or posterior
image is to be sent.
<Number of Image>: Determines number of
images to be sent per second. You can select 1, 2,
3 and 5 images per second.
<Pre-alarm Duration>: Determines time of prior
images to be sent. You can select one from <5
sec>, <10 sec>, <15 sec> and <30 sec>. You
can send a prior image of up to 30 seconds after
an alarm is generated. (The maximum time is
determined by the number of images to be sent per
second.)
6 – 36x IP Smart Dome Camera
<Post-alarm Duration>: Determines time of
posterior images to be sent. You can select one
from <5 sec>, <10 sec>, <15 sec> and <30
sec>. You can send a posterior image of up to
30 seconds after an alarm is generated. (The
maximum time is determined by the number of
images to be sent per second.)
alarM INPuT SeTuP
Various functions of 8 Alarm Inputs can be set up
independently.
Input Device Setup
❖
•
Select an input type from the <OFF>, <NO> and
<NC>.
<NO>(Normal Open): It is normally open, but if it is
close, an alarm will be generated.
<NC>(Normal Close): It is normally close, but if it is
open, an alarm will be generated.
activation Time
❖
•
You can set time to accept an alarm to take an
action.
<always>: Always conducts the <Action> setting
when an alarm is generated.
<Only Scheduled Time>: Conducts the <Action>
setting for an alarm only when it occurs during the
specified time period on the specified day of the
week. The Start Time must prior to and must differ
from the End Time.
action
❖
•
You can set an operation to be conducted when an
alarm is generated.
<alarm Output>: Determines alarm output port to
which the alarm signal is to be sent.
<Output Duration>: Determines the period of time
to output alarm signal to the specified alarm output
port when an alarm is generated. If another alarm
event is generated during the alarm output, the
delay time is recalculated on the basis of the most
recently generated an alarm.
<alarm Image Transfer>: If <On> is selected,
a JPG image is transmitted through FTP or