LIFT CORPORATION Sht. 23 of 58 DSG#
Never route an energized wire. Make sure the vehicle battery is disconnected.
Always route electrical wires clear of moving parts, brake lines, sharp edges,
and exhaust systems. Avoid making sharp bends in wiring. Attach securely. If
drilling is necessary, fi rst check behind the drilling surface to prevent damage
to any fuel lines, vent lines, brake lines, or wires.
NOTE: Use plastic loom and ties (Kit items) to secure wire extensions and protect
wire along the wire route.
Run the RED (14 AWG) wire with split loom along the
1.
trailer chassis, from fl ex loop cable on the junction box, to
rocker switch in the truck cab (FIGS. 23-1 and 24-1).
1 GA BLACK CABLE (-)
FROM PUMP (REF)
JUNCTION
BOX
RUNNING RED & WHITE WIRE TO GPSLRT PUMP BOX
© MAXON Lift Corp. 2020
GPSLRT KIT INSTALLATION
CAUTION
FLEX LOOP
CABLE
JUNCTION BOX (REAR VIEW)
RED 14 AWG WIRE & SPLIT
LOOM FROM FLEX LOOP
CABLE ON LIFTGATE
FIG. 23-1
M-19-05
Rev. A Date: 10/14/20
1 GA RED CABLE (-)
FROM PUMP (REF)
14 AWG RED WIRE
(TO CAB SWITCH)
SPLIT LOOM
ROCKER
SWITCH