SET UP REMOTE RAIN GAUGE

The rain gauge collects rain and takes readings of the total rainfall over a period of
time. The sensor can remotely transmit data to the base station.
The base station and rain gauge should be positioned within effective range: about
100 meters (328 feet) in an open area.
The rain gauge should be mounted horizontally about 1 meter (2-3 feet) from the
ground in an open area away from trees or other obstructions to allow rain to fall
naturally for an accurate reading.
To set up the sensor:
1.
Remove screws and
slide the cover up and insert the batteries (2 x UM-3 / AA),
matching the polarity (+ / -).
Press RESET after each battery change.
RESET
2. Remove the tape.
3. Put a few drops of water on the cross at the base of the funnel to check the
horizontal level.
Water will pool to the center of the cross when the rain gauge is
level.
3
If water remains on 1-4, the gauge is not horizontal.
4. If necessary, adjust the level using the screw.
NOTE For best results, ensure the base is horizontal to allow maximum drainage of
any collected rain.

SET UP BASE STATION

NOTE Install batteries in the remote sensor before the base station matching the
polarities (+ and -).
12
13
1
2
4
For continuous use, please install the AC adapter. The batteries are for back-up use
only.
NOTE Please make sure the socket-outlet is installed near the equipment and is
easily accessible.
Install the base station batteries (4 x UM-3 / AA) matching the polarity + and -. Press
RESET after each battery change.
NOTE Do not use rechargeable batteries. It is recommended that you use alkaline
batteries with this product for longer performance.
The battery icon indicator
may appear in the following areas:
AREA
Weather Forecast Area
Temperature / Heat Index /
Wind Chill Area
Wind Speed / Wind
Direction Area
UVI / Barometer / Rainfall
Area

BASE STATION

CHANGE DISPLAY / SETTING

To change the display and settings, use the following buttons: SELECT, MIN/MAX,
MODE and ALARM. In addition, the UNIT and SEARCH buttons located at the
back of the base station allows pre-setting of the remote sensor channels and the
measurement units for display.
TIP To exit from the setting mode, push any button. Alternatively, the base station
will automatically exit after 30 seconds.

CLOCK RECEPTION

This product is designed to synchronize its calendar clock automatically once it is
brought within range of a radio signal:
WMR90A:
WWVB-60 generated from the atomic clock in Fort Collins, Colorado. The radio
signal range is 3219 km (2000 miles).
Press RESET whenever you change the selected setting.
The reception icon will blink when it is searching for a signal. If the radio signal is weak
it can take up to 24 hours to get a valid signal reception.
indicates the status of the clock reception signal.
ICON
MEANING
Time is synchronized.
Receiving signal is strong
Time is not synchronized.
Receiving signal is weak
To enable (and force a signal search) / disable the clock radio reception (clock
synchronization):
1. Press SELECT to navigate to the Clock / Calendar / Alarm Area.
next to the Area.
2. Press and hold SEARCH.
appears when it is enabled.
NOTE For best reception, the base station should be placed on a fl at, non-metallic
surface near a window in an upper fl oor of your home. The antenna should be placed
away from electrical appliances and not be moved around when searching for a
signal.
4
MEANING
Battery in the base station is low.
show when AC adapter is disconnected.
The displayed channel indicates the
outdoor sensor for which battery is low.
Battery in the wind sensor is low.
Battery in the UV / Rain sensor is low.
will show