APPLICATION REQUIREMENTS
This wiring modification is for models BG770 and BG790.
FUNCTIONS
This modification provides a timer for a barrier gate operator.
The timer will close the gate after a specified time period
whenever the gate is not fully closed and all the open and safety
devices are cleared. A switch can be put on either purple wire to
defeat the timer for an extended period of time (Figure 3). The
timer is adjustable in 1 second increments from 1 second to
1,023 seconds (17 minutes).
INSTALLATION
NOTE: Refer to the gate operator owner's manual for complete
wiring diagrams.
1. Disconnect power to the operator.
2. Inside the control box, remove the wire between terminals
2 and 3 (Figure 1).
3. Install the timer in the control box using the fastening strips
(provided) or industrial strength double sided tape.
4. Connect the purple wires from the timer to terminals
2 and 3 (Figure 2).
5. Remove the jumper wire between terminals 1 and 5
(Figure 1).
6. Ensure that there is no jumper wire between terminals 8 and
9. If a close button was used, it will no longer function once
the timer is installed.
7. Test all safety devices to verify proper functionality.
8. Reconnect power to the operator.
TIMER TO CLOSE MODIFICATION
INDUSTRIAL DUTY BARRIER GATE
To prevent possible SERIOUS INJURY or DEATH from
electrocution, disconnect electric power to operator BEFORE
installing.
ALL electrical connections MUST be made by a qualified
individual.
CARTON INVENTORY
DESCRIPTION
Timer
Cable ties
Fastening Strip 1"
Purple wire
FIGURE 1
Terminal Block-BEFORE
1
2
3
4
FIGURE 2
Terminal Block-AFTER
1
2
3
4
Timer
FIGURE 3
Terminal Block
1
2
3
4
Timer Defeat
Timer
71-26438
5
6
7
8
9
10
5
6
7
8
9
10
5
6
7
8
9
QTY
1
2
2
2
10

Publicidad

loading

Resumen de contenidos para LiftMaster BG770

  • Página 1 TIMER TO CLOSE MODIFICATION INDUSTRIAL DUTY BARRIER GATE 71-26438 APPLICATION REQUIREMENTS This wiring modification is for models BG770 and BG790. FUNCTIONS To prevent possible SERIOUS INJURY or DEATH from This modification provides a timer for a barrier gate operator. electrocution, disconnect electric power to operator BEFORE The timer will close the gate after a specified time period installing.
  • Página 2 MODIFICATION PAR L’INSTALLATION D’UNE MINUTERIE SUR LA BARRIÈRE INDUSTRIELLE 71-26438 EXIGENCES D’APPLICATION Cette modification de câblage est prévue pour les modèles BG770 et BG790. Pour éviter de GRAVES BLESSURES ou la MORT, débrancher FONCTIONS l’alimentation électrique de l’actionneur AVANT l’installation.
  • Página 3 BARRERA DE USO INDUSTRIAL CON TEMPORIZADOR DE CIERRE REGULABLE 71-26438 REQUISITOS DE APLICACIÓN Esta modificación de conexiones es para los modelos BG770 y BG790. Para evitar la posibilidad de accidentes GRAVES e incluso FUNCIONES FATALES por electrocución, desconectar la energía eléctrica al Esta modificación incluye un temporizador para un operador de...
  • Página 4 © 2009, LiftMaster All Rights Reserved Touts droits réservés 01-35254B Todos los derechos reservados...

Este manual también es adecuado para:

Bg79071-26438