4-20 Ma Analog Outputs - Exlar EXP-24 Manual De Instalación Y Servicio

Tabla de contenido

Publicidad

4-20 mA Analog Outputs

The Exp 24 has two isolated 4-20mA outputs, the EXP 24 generates the voltage for the 4-20mA loop;
no external loop supply is required. The function, the range and response of the outputs can be set the
Expert Software (see Software Manual). For example the outputs are typically set to represent position
and current.
Function
4-20 mA Analog Output 1 +
4-20 mA Analog Output 1 -
4-20 mA Analog Output 2 +
4-20 mA Analog Output 2 -
Description
Range
Load
Resolution
Linearity
Isolation from PE and Supply
Typical PLC 4-20 mA Analog Input
EXP 24 Manual
PN 47676
Revision H
Terminal
J33
J34
J35
J36
Specification
4 – 20 mA
200Ω to 500Ω
12 bit (4096)
+/- 1% of 20mA
500 V
Exp 24 Isolated 4-20mA Analog Output Circuit
4-20 mA Analog Output Circuit
53
1/9/14
Exlar Corporation
952-500-6200

Publicidad

Tabla de contenido
loading

Productos relacionados para Exlar EXP-24

Tabla de contenido