Recommended airflow:
•
4"-hose
•
6"-hose
Temperature resitance:
•
Hose, continuosly
•
Hose, temporarely
Material:
•
Rubber strips
•
Suction trolley
•
Rail
•
Hose
•
Nozzle
4
Installation
4.1
Mounting instruction
Before ALU 150/250 can be installed, a suitable height and position must be
determined in relation to the vehicle's parking space in the station, see figure 1.
NOTE!
Recommended mounting height: H = 4–5 m
Then assemble the whole rail using the enclosed jointing pieces, see
figures 2–9.
4.2
Bend to rail and/or return rail
See figures 10–13.
•
A bend to suction rail
B bend to bend
•
•
C bend to return rail
D return rail to return rail
•
4.3
Fitting inner end cover
Fitting inner end cover, see figure 14.
NOTE!
Must only be used when return track is mounted.
4.4
Suspension attechments
See figure 15. Use the mounting brackets to fit the rail in ceiling beams, wall
brackets or similar. Recommended distance between the brackets: maximum
5.0 m.
Use fixing bolts and nuts suitable for load and wall or ceiling material.
Horizontal fixing force / mounting bracket = 3200 N.
Vertical fixing force / mounting bracket = 3200 N.
ALU 150/250
400 m
/h (230 cfm)
3
1000 m
/h (590 cfm)
3
150 °C (302 °F)
175 °C (347 °F)
EPDM
Aluminium/steel
Aluminium
EPDM
EPDM
EN