the mains cable is correctly assembled.
Warning! Power cable replacement must be undertaken by
the authorized service assistance centre or similar qualified
person.
Mounting
Expansion wall plugs are provided to secure the hood to most
types of walls/ceilings. However, a qualified technician must
verify suitability of the materials in accordance with the type of
wall/ceiling. The wall/ceiling must be strong enough to take
the weight of the hood. Do not tile, grout or silicone this
appliance to the wall. Surface mounting only.
Operation
The hood is fitted with a control panel with aspiration speed
selection control and a light switch to control cooking area
lights.
Fig. 11
Use the high suction speed in cases of concentrated kitchen
vapours. It is recommended that the cooker hood suction is
switched on for 5 minutes prior to cooking and to leave in
operation during cooking and for another 15 minutes
approximately after terminating cooking.
Functioning - Model with display
The electronic controls on your ducting cooker hood
have multiple functions-features:
- Motor on-off function
The motor is turned on and off by pressing pushbutton nr. 1.
When you turn on the cooker hood it automatically starts
running at the third speed.
Nr. 6 speeds
To select the required speed use pushbuttons nr. 2 and nr. 3.
The speed setting is given on the display provided for this
purpose. It is possible to modify these 6 speeds from
intensive mode "H" , display flashes, to normal mode "L". To
do this simply press pushbutton 5 (LAMP) for five seconds.
When modifying speed mode the cooker motor must be off.
- Timer function
This function permits you to program your cooker hood so that
the motor and lights turn off automatically 10 minutes after you
have activated this function. To program press pushbutton nr.
4. At the bottom on the right of the display a point will flash
indicating that the timer function is activated.
- Lights on-off function
To turn the lights on and off press pushbutton nr. 5
- Specific features
The electronic controls provided on your ducting cooker hood
have advanced features to facilitate maintenance and correct
utilization.
- Prompt - clean metal filters
After every 40 hours of use a microprocessor, heart of the
system, prompts the user that it is time to clean the metal
grease filters to guarantee better ducting performance and to
improve hygiene. This prompt is indicated by the letter "A"
which flashes on the display.
To delete this prompt, once the filters have been cleaned and
with the cooker hood off (not powered), maintain pushbutton
2 pressed for more than 5 seconds. When you press this
pushbutton the letter "A" will come up on the display and then
disappear after 5 seconds. The microprocessor zeros the
number of hours and starts a new count from zero until
reaching 40 hours prompting this maintenance procedure.
- Prompt - replace active carbon filters (if mounted)
If your cooker hood utilizes the re-circulation air filtering
system and therefore is fitted out with active carbon filters for
purifying the vapors extracted, it is necessary that you
program the microprocessor for this extraction system. To do
this, always with the cooker hood off (not powered), maintain
pushbutton nr. 4 pressed for 5 seconds. The symbol " –" will
come up on the display (this indicates the cooker hood is not
provided with a carbon filter) and after 5 seconds this symbol
changes to "C" (now indicating the cooker hood is provided
with a carbon filter). After every 80 hours of use the
microprocessor will prompt the user to replace the carbon filter.
This prompt is indicated by the letter "C" which flashes on the
display. This is to guarantee better filtering performance and
to improve hygiene.
To delete this prompt, once the filters have been replaced and
with the cooker hood off (not powered), maintain pushbutton
3 pressed for more than 5 seconds. When you press this
pushbutton the letter "C" will come up on the display and then
disappear after 5 seconds. The microprocessor zeros the
number of hours and starts a new count from zero until
reaching 80 hours prompting this maintenance procedure.
23