The Super Fog Nano was designed specifically for small terrariums. The humidifier
is small and compact and uses low-voltage technology, so that maximum safety
is ensured. Attention: Do not use the device inside a terrarium! The hu-
midifier is designed for installation outside of the terrarium and not
suitable for use in high humidity surroundings! The device is based on the
proven technology of the Super Fog and has a ceramic membrane, that nebulizes
water through ultrasonic vibration.

Operating conditions:

• The device may only be operated at 12V / 1,5A DC Voltage.
• Install the device in a suitable place and make sure it has a secure footing.
• The ambient temperature limit during operation may not fall below and exceed
0°C and 60°C respectively.
• The device is designed for use in dry and clean rooms.
• Protect the device from moisture, spray water and impact of heat!
Instruction for use:
• Attach the tube to the outlet and install the other end of the tube inside of
the terrarium. The plastic tube can be stretched to a length of 1 m and bent
as desired.
• The maximum difference in height should not be more than 1 meters (see Fig. 2)
• Screw the water tank and fill it up to the white marking with water (H2O Terra
Tec (NOTE: In case of exceeding the „MAX" mark or when the water
level remains below the membrane, the device has no function)
• Screw the water tank to the humidifier
• Before putting the humidifier on, a secure footing has to be ensured so that it
can't fall over.
• The humidifying degree can be adjusted with the Power switch, If turned on, a
red light will show.
• It is recommended to use a timer as Lucky Reptile Easy Timer or even better a
hygrostat as Lucky Reptile Humidity Control or other control unit. It isn't desi-
gned for Continuous use.
• It is recommended to use Lucky Reptile Terra Tec H2O water to ensure a long life,
because the minerals in tap water will damage the membrane.
Failure Checking and Fixing:
If your humidifier fails to work:
Failure
Indicator lamp not on, no fog
Fog has strange smell
Low fogging power
Abnormal noise
Should the problem reside, contact your retailer.
Manual – Super Fog Nano Humidifier
Failure analysis
No power
Water level indicator not under water or too much water
New device
Dirty or old water
Dirty or damaged membran
Dirty or old water
Low water in tank
Vibrations due to unsecure footing
Security advice:
• Power cable, the switch and the socket have to be checked regularly for da-
mages. In case of damage the humidifier has to be put out of operation im-
mediately or rather may not be put into operation. The same action should be
taken if the humidifier came into contact with fluids. Checking and if necessary
repairing the device may only be done by a qualified expert!
• Generally it should be verified if the device is applicable for the application at
hand before putting it into operation! In case of doubt consultation of experts
or the manufacturer of the employed devices is required!
• Use in terraruim or outdoors is not allowed.
• Cut power if you remove the water tank or before moving the device
• For connection only the transformer supplied by the manufacturer may be used.
• Do not use hard devices for cleaning the membrane to avoid damage
• Keep the device away from electromagnetic sources
• Do not open the device or make any technical changes
• The Humidifier may not be operated in rooms with high humidity.
Changing the membrane: The membrane wears out over time and needs to be
replaced. The replacement of the membrane can only be made by a professional.
Please contact us if your membrane needs to be replaced. This is not covered by
any warranty!
Warranty:
The implied warranty applies. The warranty does not cover the membrane. The
warranty is void if used improperly or if the device has been tampered with!

Technical Data:

Humidifying Performance:
Water Tank capacity:
Operating Voltage::
Powet Consumption:
Dimensions:
Weight:
Solution
Connect power, turn on
Refill water or drain water
Open the water tank and ventilate for 12h in a cool place
Change water and clean tank/device
Clean carefully the membrane, or let it be replaced by a
professional
Clean tank/device and change water
Refill water tank
Place device on noise reduction surface
<= 100 ml/h
140 ml
230 V AC 50/60 Hz
<= 15 W
ø 85 x 145 mm
0,22 kg