Commercial Electric MS602H Guía De Uso Y Cuidado página 3

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Operation (continued)
2
TESTING A BATTERY
Set the battery selector (C) to the
type of battery you are testing.
IMPORTANT: If the battery selector
(C) is incorrectly positioned, an
inaccurate test will result and
may damage the tester and cause
excessive drain on the battery.
Touch the red test lead (A) to the
positive (+) terminal on the battery,
and the black test lead (B) to the ne
gative (–) terminal on the battery.
Observe the battery condition on the
indicator scale (D) as indicated by
the needle.
When testing 9-volt rectangular
batteries, position the positive (+)
and negative (–) battery terminals
directly onto the positive and
negative contact points (F and G).
Then observe the battery condition
on the indicator scale (D).
3
ALTERNATE TESTING METHODS
Depending on the battery type, it may
be easier to use the positive and
negative contact points (F and G) on
the tester instead of touching both
test leads to the positive and negative
terminals on a battery.
Position the positive (+) terminal of the
battery on the positive contact point (F).
Then touch the black test lead (B) to the
negative (–) terminal of the battery and
observe the battery condition on the
indicator scale (D).
The reverse can be done by positioning
the negative (–) terminal of the battery
on the negative contact point (F) and
touching the red test lead (A) to the
positive (+) terminal on the battery.
F
G
D
C
A
D
F
B
D
A
HOMEDEPOT.COM
5
Please contact 1-877-527-0313 for further assistance.
Operation (Continued)
4
TESTING BUTTON CELL BATTERIES
Insert the battery, negative (-) side
up, in the slot below the pushbutton (H).
D
Press down on the pushbutton (H) to
make contact with the positive and
negative terminals on the battery.
Read the battery condition on the
indicator scale (D).
B
5
READING THE INDICATOR SCALE
When testing nickel-cadmium
rechargeable batteries, read the
bottom portion of the indicator scale
(D) marked NICKEL CADMIUM.
When testing button cells and lithium
batteries, read on the middle portion
of the indicator scale (D) marked
BUTTON CELL - LITHIUM.
When testing all other batteries, read
the top portion of the indicator scale
(D) marked REGULAR.
D
D
D
D
6
H

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

120 196