5.3 Electrical components
•
Risk of death in case of interrupted protective conductor!
–
–
–
•
Risk of death from connecting power supply units in series!
Contact voltages of greater than 25 V AC or 60 V DC are not permissible.
Coming into contact with voltages of greater than 50 V AC or 120 V DC
may be fatal.
–
•
Risk of death due to electric shock!
Protect the outputs of the power supply units (output sockets/terminals) and
cables connected to them from direct contact.
–
–
Danger of electric shock
Electric shock due to high leakage current
• Operate the device only with a second protective grounding conductor
© Festo Didactic 8121048
The protective grounding conductor (yellow-green) must not be interrupted,
neither inside nor outside of the device.
Due to the high leakage current, operation is only permitted with a second
protective grounding conductor.
The insulation of the protective conductor must never be damaged or
removed.
Do not connect voltage sources in series.
Use only cables with adequate insulation and electric strength.
Use safety sockets with fully shrouded contact points.
WARNING
WARNING
Servo brake and drive system
53