there will be a delay of electrical output for 15
seconds.
If the engine fails to start within 3 to 5 seconds, the
engine will attempt to start five additional times. If
the generator failed to start, the remote start
indicator light will flash.
If the generator fails to start after a total of six
attempts, the start button on the remote control
must be pushed again to begin another cycle of six
start attempts.
8. Allow generator to run at no load for few
minutes upon each initial start-up to permit
engine and generator to stablize.
Connecting Electrical Loads
This unit has been pretested and adjusted to
handle its full capacity. Before starting the
generator, disconnect all load. Apply load only
after generator is running. Voltage is regulated via
the engine speed adjusted at the factory for
correct output. Readjusting will void warranty.
CAUTION
When applying a load, do not exceed the
maximum wattage rating of the generator when
using one or more receptacles. Also, do not exceed
the amperage rating of any one receptacle.
Do not apply heavy electrical load during break-in
period (the first five hours of operations).
1.Let engine stabilize and warm up for a few
minutes after starting.
2.Ensure circuit breaker on control panel is in
position.
3.Plug in and turn on the desired 120 or 240 Volt
AC, single phase, 60Hz electrical loads. It is
to attach the item with largest load first.
English
1. Turn off and remove entire electrical loads.
Never start or stop the generator with
electrical devices plugged in or turned on.
on
Let the generator run at no-load for two
minutes to stabilize internal temperatures
better
engine and generator.
2. Remote Start Operation
Note: Skip this step and go to step 3, if you are not
using Remote Start to shutdown the engine. Push
and release the "STOP" button on the remote
control. The generator will run for an additional 15
seconds as it goes through a cool down cycle
before shutting off.
Customer Service: 1-844-FIRMAN1Page 14