Connection; Electrical Connection - Ideal Standard VExxP1-SOFT TUB Manual De Instalación, Uso Y Mantenimiento

Tabla de contenido

Publicidad

- When appropriate, he must install the device(s)
for prevention of backflow in accordance with
EN 1717.
- In the case of a failure or malfunction he must
contact After-Sales Service who will supply
original spare parts.
The manufacturer is not liable if the whirlpool tub
is installed on premises where the structures and
systems are not to standard or for work performed
by unqualified or unskilled personnel.
The electrical specification of the whirlpool
with the CE mark and relative rating plate
values are given on the label on the edge of
the box. Under no circumstances must this
label be removed.
- We also suggest periodically testing the opera-
tion of the differential switch by pressing the
"TEST" button.
- Staying too long in the whirlpool may cause
a drop in blood pressure or excessive muscle
relaxation.
- If used by children, an adult must be present
at all times.
- Do not under any circumstances use liquid
soaps that create suds.
e
lectrIcal connectIon
ATTENTION!
Prior to installation, check that the electrical system
is compliant with standards and laws in effect
and that it is equipped with a magneto-thermal
differential switch with a breaking capacity of 16A
and a differential of 30mA.
Connection must be made in a fixed and perma-
nent manner, with no intermediate connections,
by installing an omnipolar 16A disconnecting
switch with minimum aperture distance of con-
tacts which allows complete disconnection in
conditions of category III, outside of zones 0-2-2-3
and protected from water splashes (60 cm laterally
beyond the side of the tub or at height of 225 cm
from the floor) (Fig. 1).
TT0283385_02_SOFT_CMYK.indd 83
Safety distances and clearances
Zone 1
Zone 0
Zone 2
Zone 3
Parts containing live components, with the excep-
tion of those parts powered at very low voltage
(i.e. not exceeding 12V) must not be accessible to
persons using the tub.
All parts containing electrical components, with
the exception of remote control handsets, must
be positioned or fixed in such a way as to ensure
that they cannot fall into the tub. The power cable
must be protected inside the wall, right up to the
control unit, by a corrugated tube or other system
that complies with current standards and certified
by the CE directive.
The power cable must not be less than type
H05VV-F tripolar with a section of at least 1.5
mm
.
2
Fig.2
83 83
5-07-2010 16:34:11

Publicidad

Tabla de contenido
loading

Tabla de contenido