5.9. After a long break in the work of the cabinet, it can only be put into operation after a thorough
check by a representative of the service center.
5.10. Do not touch the running product with wet hands, feet or if you walk barefoot.
5.11. The operation of the cabinet mounted on the conductive floor must be carried out from
insulating areas (rubber mats or other dielectric materials).
5.12. IT IS FORBIDDEN to operate the cabinet with removed or defective automation devices,
as well as in case of damage to the insulation of electrical wires and the break of the ground wire.
5.13. IT IS FORBIDDEN to operate the cabinet with the removed aggregate compartment
grating.
5.14. IT IS FORBIDDEN to use the cabinet, whose glass doors are damaged and have sharp
edges.
5.15. IT IS FORBIDDEN to operate the cabinet in rooms with increased danger, characterized
by the presence of one of the following conditions:
special dampness or conductive dust (rooms in which air humidity is above 80%,
when walls, ceiling, floor and objects in the room are covered with moisture);
chemically active medium (rooms in which permanently or long-term contain or form
sediments acting destructively on the insulation and current-carrying parts of
electrical equipment)
5.16. IT IS FORBIDDEN to wash the product under running water.
5.17. IT IS FORBIDDEN to touch the cabinet and devices that have a natural ground (heating
radiator, water pipe, etc.).
5.18. IT IS FORBIDDEN to modify the power cord by yourself. Replacement of the power cord
must be carried out by an employee of the repair organization who has a document for the right
to perform such work.
5.19. ATTENTION! In order to ensure fire safety, please observe the following: at least once a
year, clean the accumulated dirt and dust with a dry soft brush or vacuum cleaner parts located
at the bottom of the cabinet. STRICTLY FORBIDDEN the wet cleaning in this area
in the process of operating or cleaning the cabinet, or when sanitizing the room, do not allow
moisture to enter the compressor and electrical wiring. If moisture accidentally falls on these
parts, the product may only be switched on after a full drying of the moisture!
6. OPERATING AND MAINTENANCE MANUAL
6.1. After connecting the product to the mains in accordance with the above rules, you can start
it from the control panel and the necessary adjustment.
Note: pre-start preparation, connection of the network and adjustment of the controller must be
performed by the representative of the service center, certified for this type of work.
Attention! After transportation at a temperature below + 10 ° C, the equipment must be kept at
an ambient temperature of + 18 ° C to + 25 ° C for at least 4 hours before switching on.
Re-inclusion of equipment into the mains (after an emergency shutdown) must be performed no
earlier than 3-4 minutes. after it is turned off.
6.2. The control panel is shown in Fig.2.