ESPECIFICACIONES DE INSTALACIÓN (continuación)
Drawing Title: LS-B-159-4000-08
INSTALACIÓN DE LA PLACA DEL EYECTOR
B
NOTES:
1.
EJECTOR AND TRANSFER PIN CONCENTRICITY MUST BE WITHIN 0.030" [0.76] OR
10% OF EJECTOR PIN DIA, WHICHEVER IS SMALLER.
2.
DO NOT SCALE PRINT
3.
BREAK ALL SHARP EDGES, 0.005 [0.03] R MAX
4.
DIMENSIONS IN INCHES [MM], UNLESS NOTED
5.
TOLERANCES UNLESS SPECIFIED:
XXX = 0.003 [0.08]
XX = 0.01 [0.3]
ANGLES = 3 30
Manual del Producto | Galga Extensométrica Monocanal Lynx ™ 4000 Libra Sensor de Botón LS‑B‑159‑4000
LS-B-159-4000 Single-Channel Sensor Installation—Ejector Plate Installation
B-Plate or Cavity Insert
Ejector Pin—Installed with Normal
Slip-Fit Tolerances H7/g6
Ejector Retainer Plate
Ejector Plate
0.001 [0.03] B
0.001 [0.03]
0.001 [0.03] A
0.001 [0.03]
Clamp Plate
Ejector Pin Ø
0.04–0.08 [1.0–2.0]
0.10–0.20 [2.5–5.0]
0.24–0.40 [6.0–10.0]
0.01 MIN
Per Side
0.3 MIN
+
0.005
0.635
-
0.000
[16.13 0.1]
B
A
45°
REFER TO
TABLE O
TABLE O
Chamfer Length
DETAIL B
0.01 [0.3]
SCALE 3 : 1
0.02 [0.4]
0.025 [0.6]
Ejector Pin Head Ø +0.125 [3]
if DIA ≥ 0.625 [15.88]
Part Thickness < 0.05 [1.5], 1/5 of Thickness
Part Thickness > 0.05 [1.5], 0.01 [0.3]
0.020 MIN
0.5 MIN
+
0.002
0.500
-
0.001
[12.7 0.04]
R0.005 MAX
0.1 MAX
Description: LS-B-159-4000
Sensor Installation
Drawn: K.J.Brettschneider
Design:
Check: M.Groleau
Date: 11.18.2021
RJG, Inc.