Commissioning And Operation; Making Settings - Aventics EtherCAT Instrucciones De Servicio

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 173
B
A
AVENTICS | EtherCAT | R412012792–BDL–001–AB
1
Fig. 5:
FE connection on the bus coupler (1)
7
Commissioning and
operation

7.1 Making settings

The following presettings need to be made:
Selecting the valve supply
W
Setting the diagnostic messages
W
All of these settings are made using the switch beneath
fittings A and B.
Proceed as follows with all presettings:
1. Remove the fitting.
2. Adjust the corresponding setting as described below.
3. Screw the fitting back in (0.6 + 0.2 Nm). Pay attention
that the sealing rings are positioned correctly.