EdmoLift Products Manual
Fault
The lift table does not lower.
The lift table lowers without DOWN-
button being pressed.
Lifting or lowering speeds faster or
slower than desired.
Copyright © EdmoLift AB 2004-2007
All rights reserved. No part of this publication may be reproduced, stored in a retrie-
66
val system, or transmitted in any form or by any means, electronic, mechanical,
photocopying, recording or otherwise without the permission of the publisher.
Reason
Incorrect electrical wiring.
E-STOP button has been actuated.
The safety frame has been activated.
Primary or secondary line fuses actua-
ted.
The lowering valve does not open.
Dirt in the hydraulic system
The oil volume decreases due to oil
cooling.
Flow control valve not correctly set.
2005-02-01
Action
Check the connections.
Turn the button clockwise to release.
Remove any trapped obstacle. Press
the UP-button briefly to reset, then the
lowering button again
Check reason and reset.
Check the electric circuit. Possibly the
valve cartridge or solenoid coil need to
be replaced.
1. Operate the lift a few cycles to
remove any contaminants from the
valve seating.
2. Dismantle the lowering valve, check
valve cartridges and clean these.
3. Replace the lowering and check
valve cartridges and change to new
oil.
Quite normal. If it is an inconvenience,
contact EdmoLift for proposal to solve
this.
Adjust the flow control valve
NOTE! High speed means increased
risk for instable goods.