Scope Of Delivery; Intended Use; Installation And Connection; Remedy Of Faults - Pontec PondoSolar 1600 Instrucciones De Uso

Ocultar thumbs Ver también para PondoSolar 1600:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 16
- EN -

Scope of delivery

 A
Quantity
1
1
2
2
3
2
4
1
5
1
6
2
8
3
7
1
√√√√

Intended use

PondoSolar 1600, referred to as "unit", may only be used as specified in the following:
• For creating a water fountain in a pond.
• For operation with clean water.
• Operate in accordance with instructions.
The following restrictions apply to the unit:
• Never use the unit to convey fluids other than water.
• Never run the unit without water.
• Do not use in conjunction with chemicals, foodstuff, easily flammable or explosive substances.

Installation and connection

How to proceed:
 B
1. Screw the transition piece onto the pump outlet.
2. Assemble the nozzle unit and fit it onto the transition piece.
– Adapt the number of nozzle extensions used to the depth of the pond.
3. Connect the connection cable to solar module 1.
– Push the plug completely into the socket (up to the stop) to ensure that the connection is watertight.
– Switching on: Connect the pump to the solar module.
– Switching off: Disconnect the solar module from the pump.
4. Connect both solar modules together using the connecting cable.
– Push the plug into the socket as far as possible to ensure that the connection is watertight.
5. Assemble the ground stake set and attach it to the solar module.
– Ensure that the connection cable is routed downwards.
6. Install the solar module so that it is exposed to direct sunlight.
– Recommendation: Align the solar module to the sun to ensure maximum energy yield.
7. Fix the pump underwater to a smooth, clean surface using the suction cups.

Remedy of faults

Malfunction
Pump does not start.
Insufficient or no pump delivery
8
Description
Pump with 5 m connection cable
Solar module
Ground stake set
Connecting cable for solar module
Nozzle holder
Nozzle attachment
Nozzle extension
Transition piece
Cause
No connection to the solar modules or the solar modules
are not connected to each other.
The solar module is soiled.
The impeller unit is blocked.
Insufficient sunlight
The filter is clogged.
The nozzle unit is clogged.
The impeller unit is worn.
Insufficient sunlight
Remedy
− Check the connection to the solar module.
− Connect the pump to the solar module.
− Push the plug into the socket as far as
possible.
Clean
Clean
Remove the filter housing, remove and clean
the filter.
Remove and clean the nozzle unit.
Replace
Align the solar module to the sun.

Publicidad

Tabla de contenido
loading