5.3 PROGRAMMING.
Configuration of 4 different programs: "Reduced", "Cyclic", "Progr_
1" (personalised) e "Progr_2" (personalised) .
• REDUCED.
For programming a single switch-on and a single switch-off event
during the day .
• CYCLIC.
For programming a switch-on and a switch-off period that are re-
peated cyclically .
For example, entering "On hh mm 1.15" and "Off hh mm 1.30",
the contact will continually repeat the sequence "contact ON for 1
hour and 15 minutes" - "contact OFF for 1 hour and 30 minutes" .
• PROGR_1 e PROGR_2.
Personalised programs . For setting up 2 different switch-on and
switch-off programs for each individual day of the week, for a
maximum of 35 switch events a day .
Confirm "ok" (button D) = scrolling menu with a choice of "Modi-
fy", "Copy" and "Rename" .
- Modify.
Allows the user to set up or edit the switch-on and switch-off pro-
gram, if desired by copying a program from one of the other days .
14 - ENGLISH
All manuals and user guides at all-guides.com
- Copy.
For copying a program that has already been configured by the
user into one of the programs that is still to be configured .
- Rename.
For assigning a name to or renaming the chosen program .
6. RESET PROCEDURE.
• Simultaneously press the four buttons (button A, button B, button
C, button D)
• Confirm with "Yes" (button D) .
Restores the original first power-up conditions; all parameters are
reset to their default values .
7. CHARACTERISTICS.
• Supply voltage: 120-230 V~ ± 10% 50-60 Hz
• Absorption max: 1 W
• Front controls: "Esc", "", "", "Set"/"ok"
• Clock backup battery duration: about 20 days, with rechargeable
lithium buffer battery
• Output: 8 A 230 V~ change-over relay output
• controllable loads:
- purely resistive loads
: 8 A
- incandescent lamps
: 800 W
- magnetic core transformers for very low voltage incandescent