Test certificate
DVGW
14475XXX
X
14477XXX
14675XXX
X
31475000
X
31476000
31675000
X
31744000
X
31761000
X
33455000
X
33457000
X
33655000
X
Fault
Mixer stiff
Mixer dripping
Diverter not operating
Hot water temperature too low,
no cold water.
Instantaneous water heater starts
up when cold water is selected.
P-IX
SVGW
PA-IX
X
9709/ICC
PA-IX
18097/IDC
PA-IX
X
9710/IB
PA-IX
X
9709/ICC
PA-IX
18097/IDC
PA-IX
X
9710/IB
PA-IX
X
9709/IDC
PA-IX
X
9710/IB
PA-IX
X
9709/IDC
PA-IX
X
18097/IDC
PA-IX
X
9710/IB
Cause
-Cartridge defective, calcified
-Cartridge defective,
sedimentation
-Water pressure to low
-Diverter defective
-Hot water limiter incorrectly set
-Crossflow
English
NF
X
X
X
WRAS
KIWA
X
X
X
X
X
X
X
Remedy
-Exchange cartridge
-Exchange cartridge
-Increase water pressure
-Exchange diverter
-Set hot water limiter
-Exchange cartridge