nedis DTCTCO40WT Manual Del Usuario página 10

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 42
Concentration of CO
in air. (ppm = parts per
million)
400ppm
800 – 999 ppm
-
The product is designed to protect users against
the acute effects of CO poisoning. The product does
not ensure complete protection for people with
medical issues.
Installing the batteries (image B)
1. Turn the alarm A
5
counter clockwise to remove it
from the bracket A
6
2. Insert the batteries into the battery compartment.
Make sure that the battery polarity (+/-) matches the
polarity markings inside the battery compartment.
3. Turn A
clockwise to attach it to A
5
-
Constant exposure to high or low humidity may
reduce battery life.
Mounting the product (image C + D)
1. Turn A
counterclockwise to remove it from A
5
2. Place A
6
in the desired location.
Symptoms
Within 1-2 hours of
exposure:
-
frontal headaches
WARNING: 3 hours of
exposure will result in
death.
Within 45 minutes of
exposure:
-
dizziness
-
nausea
-
convulsions
-
unconsciousness
WARNING: 2-3 hours
of exposure will result
in death.
.
6
.
Follow steps 3-5 for stone/concrete surfaces. Continue
to step 6 for wood surfaces.
3. Use A
6
4. Drill two Ø 5 mm holes.
5. Insert the plugs A
6. Fasten the mounting bracket with the screws A
7. Turn A
5
Make sure the arrow on the bracket is pointing upwards
when installing to the wall.
Keep the product in a dust free area when drilling.
4
Do not overtighten the screws, this will deform the
bracket.
Choosing a location (image E + F)
For safe use, it is recommended to install the product in
the following locations:
• Every sleeping area.
• Both ends of a hallway longer than 12 m.
• Every room where multiple people spend several
consecutive hours.
• Install at least one product on each floor of a
multi-level home.
• Every room where a furnace, a heat source and/or
other burning devices are located.
• If there is a basement in the house: At the top of the
basement stairs.
-
The product only indicates the presence of CO near
the sensor. CO may be present in other areas.
In areas with a source of combustion
On the ceiling:
• At least 1 - 3 m away from the CO-source. The
optimal distance is 6 m.
• At least 30 cm away from surrounding walls.
• At a central point in the room.
.
• Not in turbulent air (near windows, ceiling fans or air
6
conditioners).
10
to mark the drill locations with a pencil.
q
into the holes.
clockwise to attach it to A
.
9
6
.

Publicidad

Tabla de contenido
loading

Tabla de contenido