HEATER STAND AND LOCATION
The use of this appliance in enclosed areas is dangerous and not
allowed.
This appliance is only for use outdoors or in amply ventilated areas.
An amply ventilated area must have a minimum of 25% of the
surface area open.
The surface area is the sum of the walls surface.
Make sure that the following minimum distance between wall and
ceiling are observed.
Minimum distance between wall and device is 70 cm (28")
Minimum distance between ceiling and device is 45 cm (18")
The heater is primarily for outdoor use only. Always ensure that adequate fresh air ventilation is
•
provided.
•
Always maintain proper clearance to combustible materials, i.e. top 45 cm (18") and sides 70 cm
(28") minimum.
Heater must be placed on level firm ground.
•
•
Never operate heater in an explosive atmosphere like areas where gasoline or other flammable
liquids or vapors are stored.
To protect heater from strong wind, anchor the base securely to the ground with screws.
•
Otherwise heater would tilt.
GAS REQUIREMENTS
Use LPG gas mixtures.
•
Maximum inlet pressure of propane regulator must not exceed 6.9 Bar (100 PSI).
•
•
The pressure regulator and hose assembly to be used must conform to local standard codes.
The installation must conform to local codes, or in the absence of codes, with standard codes.
•
The installation must conform to local codes, or in the absence of codes, with the standard for
•
storage and handling of liquid petroleum gases.
A dented, rusted or damaged propane tank may be hazardous and should be checked by your
•
tank supplier.
•
Never use a propane tank with a damaged valve connection.
The propane tank must be arranged to provide for vapor withdrawal from the operating cylinder.
•
Never connect an unregulated propane tank to the heater.
•