GE GXOF18K Manual Del Usuario página 21

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Before you call for service...
Troubleshooting Tips
Problem
Possible Causes
Salty tasting or
Unit not sanitized
brown/yellow colored
water after installation
Low water pressure
Restricted drain hose
Brown/yellow
Unit was idle for a period of time
colored water
Resin beads showing
Cracked distributor
up in drinking water
and sink
Sounds you might hear
Running water from the unit
into a drain during recharge
Water has air bubbles
Air in system after installation
and is cloudy
Error Code on control
Wiring may have worked loose
in the control
Blue light flashing
When power applied
Control needs to be programmed
to the system
(a power outage may have occurred)
If "DAYS TO EMPTY"
Low salt level, less than 15 days
is flashing
If "Err" in display
Electrical problem with system
20
All manuals and user guides at all-guides.com
What To Do
• Complete the Sanitization Procedures on page 10.
• At completion of recharge cycle (approx. 2 hrs), run water
• Check pressure; should be minimum1.4 Bar.
• Clean and reconnect hose.
• Check for kinks in drain line.
• Complete the Sanitization Procedures on page 10.
• Call for service.
• This is normal.
• Will go away after it runs for a while.
• See page 14 for details.
• Unplug transformer.
• Remove control cover, release clips on side.
• Check for loose/incorrect wiring connections to electronic
• Reassemble control cover.
• Plug in Transformer.
• Wait six minutes for Error Code to reappear.
• If Error Code reappears, call for service.
• See the Programming the Control section, page 8.
• Fill with salt.
•Reset salt level.
• See page 14 for details.
•See procedure above, Error code on control.
from faucets to purge the salty water.
board or switch. Reconnect as required.

Publicidad

Tabla de contenido
loading