Do not allow water to remain in the water pipes if the unit is not operating for a long period.
Water must be drained out if the unit is not running during winter. Failing to do so would cause the pipe to crack.
Do not drink the chilled water in the unit.
Refer to the wiring diagram provided on the unit when making electrical wiring. See page iii / iv.
Table B : ( R410A - Heatpump )
Model
Power Supply
Voltage range
Nominal Power Input (Cooling/Heating)
Nominal Current Input (Cooling/Heating)
Maximum Continous Current (Comp 1/2)
Full Load Current (Comp 1/2)
Pump Power Input (Cooling/Heating)
Model
Voltage Range **
Recommended Fuse *
Power Supply Cable Size *
Number of Conductor
Interconnection Cable Size *
IMPORTANT : * The figures shown in the table are for information purpose only. They should be checked and selected to
comply with the local/national codes of regulations. This is also subjected to the type of installation and
conductors used.
** The appropriate voltage range should be checked with label data on the unit.
All field wiring must be installed in accordance with the national wiring regulation.
All the terminals and connections must be tightened. Improper connection and fastenings could cause electric shock,
short circuit and fire.
Ensure that the rated voltage of the unit corresponds to that of the name plate before commencing wiring work
according to the wiring diagram.
The unit must be GROUNDED to prevent possible hazards due to insulation failure. Do not ground any electrical
equipment to the water piping.
All electrical wiring must not touch the refrigerant piping, compressor, pump, fan motor or any moving parts of
the fan motors.
Do not operate the chiller with wet hands. It would result in electric shock.
Do not use fuse of different amperage than stated. Using wire etc. to replace a fuse could cause equipment damage
or fire.
Neutral wire size must be 3 times larger than the incoming live wire size.
All manuals and user guides at all-guides.com

! ! ! ! ! CAUTION

ELECTRICAL AND WIRING

ELECTRICAL DATA

5AC030CR
V-ph-Hz
400 / 3 /50
V
380 ~ 420
kW
3.7 / 3.6
A
5.6 / 5.5
A
12.5 / 12.5
A
35.2 / 35.2
W
199 / 214

RECOMMENDED FUSE AND CABLE SIZES

5AC030CR
A
2
mm
mm
2
1.5
! ! ! ! ! CAUTION
1-3
5AC040CR
5AC050CR
400 / 3 /50
400 / 3 /50
380 ~ 420
380 ~ 420
4.3 / 4.5
5.1 / 5.1
6.8 / 7.0
7.7 / 7.8
12.5 / 18.3
15.4 / 19.4
35.2 / 67.0
58.0 / 68.0
312 / 322
339 / 347
5AC040CR
5AC050CR
380 ~ 420V /3Ph /50Hz + N + !
25
29
10
10
3
3
1.5
5AC055CR
400 / 3 /50
380 ~ 420
5.3 / 5.4
8.3 / 8.5
19.4 / 19.4
68.0 / 68.0
345 / 353
5AC055CR
33
36
10
10
3
3
1.5
1.5