5.2 POSITIONING
‼
The appliance must be installed in a hygienically clean location; it is advisable to avoid
rooms like cellars and store-rooms, because failure to meet hygiene requirements is likely to
lead to the formation and proliferation of bacteria in the appliance.
It is advisable to install the appliance in a room where the temperature is between 50°F (10°C)
and 95°F (35°C), and with a water supply temperature of between 38°F (3°C) and 77°F (25°C).
Avoid installing the appliance where it may be exposed to direct sunlight or near heat sources
such as radiators, stoves, dishwashers, etc.
‼
This appliance:
• must not be used outdoors
• must not be installed in damp places or where it is liable to be sprayed with water
• must not be cleaned with jets of water
• allow a clearance of at least 2 inches (5 cm) all around the appliance
5.3 CONNECTION TO THE WATER MAINS
‼
IMPORTANT:
the appliance must be connected to the water mains by professionally qualified personnel in
•
accordance with the Manufacturer's instructions
this appliance must be only be supplied with cold water for human consumption (drinking water)
•
the operating pressure must be between 14.5 and 87 PSI (0.1 and 0.6 MPa)
•
a tap must be installed between the water mains and the feed pipe of the appliance, so that the
•
water supply may be shut off if necessary
where the feed water is particularly hard, you are advised to install a softener. Any solid particles
•
(e.g. sand) may be eliminated by installing a mechanical filter, which must be periodically inspected
and cleaned. These devices must comply with local standards
never turn the water supply tap off when the appliance is working
•
5.3.a WATER SUPPLY (Fig. 6)
Connect water supply solenoid valve (11) located at the back of the appliance to the mains water
supply in accordance with local regulations
5.3.b DRAIN (Fig. 6)
Connect drainage connector (12) located at the back of the appliance to the sewer network in
accordance with local regulations. Check that:
• the water drain hose is not throttled at any point throughout its length
• the drain hose slopes downwards by at least 15%
5.4 CONNECTION TO THE ELECTRICITY MAINS
‼
IMPORTANT:
the appliance must be connected to the electricity mains by professionally qualified
•
personnel in accordance with the local laws in force
before connecting the appliance to the electricity mains, make sure that the mains voltage rating
•
corresponds to the value indicated on the rating plate
make sure that the appliance is connected to an efficient earthing system
•
make sure that the capacity of the power supply system suits the maximum power value indicated
•
on the rating plate of the appliance
the appliance is supplied with a plug; prepare a specific socket controlled by an omnipolar
•
thermomagnetic circuit breaker (7 in Fig. 5) conforming to local safety regulations, fitted with fuses,
with associated differential, positioned in such a way that it can easily be reached. Insert plug into
socket controlled by switch (7 in Fig. 5)
the plug must only be replaced by professionally qualified and authorized personnel, and the
•
new plug must comply with current local safety standards